Evaluation of Headspace Solid-Phase Microextraction for Analysis of Phosphine Residues in Wheat

Author:

Ren Yong Lin1,Padovan Benjamin2,Desmarchelier James M3

Affiliation:

1. Cooperative Research Centre for National Plant Biosecurity, Canberra, Australia Murdoch University, School of Biological Science and Biotechnology, S. St, Murdoch, WA, 6150 Australia Department of Agriculture and Food, Western Australia, 3 Baron Hay Court S., Perth, WA 6151, Australia

2. CSIRO Entomology, GPO Box 1700, Canberra ACT 2601, Australia

3. 19 Guilfoyle St,Yarralumla, Canberra ACT 2600, Australia

Abstract

Abstract In headspace (HS) analysis, a fumigant is released from a commodity into a gas-tight container by grinding, heating, or microwaves. A new technique uses HS-solid-phase microextraction (SPME) for additional preconcentration of fumigant. HS-SPME was tested for detection of phosphine (PH3), chosen for examination because of its wide use on stored commodities. PH3 was applied to 50 g wheat in separate 250 mL sealed flasks, which were equipped either with a septum for conventional HS analysis or with one of four HS-SPME fibers [100 μm polydimethylsiloxane (PDMS), 85 μm carboxen (CAR)/PDMS, 75 μm CAR/PDMS, and 65 μm PDMS/divinylbenzene (DVB)]. The wheat was heated at 45°C for 20 min. In conventional HS analysis, a gaseous aliquot (80 μL) was taken from the HS and injected into the GC instrument. In the HS-SPME procedure, the fiber was removed from the HS and exposed in the heated injection port of the GC instrument. In all cases, PH3 was determined under the same chromatographic conditions with a GC pulsed flame photometric detector. In a comparison of the efficacy of the fibers, the bipolar fibers (CAR/PDMS and PDMS/DVB) contained more PH3 than the aliquot in the conventional HS analysis; larger size bipolar fibers extracted PH3 more efficiently than smaller fibers (e.g., 85 > 75 > 65 μm). The nonpolar fiber (PDMS) contained no PH3. Four fortification levels of PH3 on wheat were tested: 0.01, 0.05, 0.1, and 0.3 μg/g. The response of each bipolar fiber increased with the fortification levels, but the conventional HS analysis detected no fumigant at the lowest fortification level of 0.01 mg/g. Under the conditions of the validation study, the LOD was in the range of 0.005–0.01 ng PH3/g wheat.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3