Affiliation:
1. Medical University in Lublin, Department of Physical Chemistry, 4A Chodźki St, 20-093 Lublin, Poland
Abstract
Abstract
In this study, a simple, cost-effective, and sensitive HPLC diode-array detection method was developed for the simultaneous determination of six different 5-nitroimidazoles [metronidazole, 2-hydroxymethyl-1-methyl-5-nitro-1H-imidazole, dimetridazole (DMZ), ronidazole, ornidazole, and ipronidazole] in bovine milk samples. A QuEChERS-based sample preparation procedure was optimized by evaluating different cleanup sorbents, including zirconium-based sorbents (Z-Sep and Z-Sep+), C18, and primary–secondary amine (PSA), as well as EMR-Lipid cleanup solution. Acceptable analytical performance for all analytes was observed with recoveries in the range of 45–93% and RSDs of less than 15%. Negligible matrix interference was observed for most of the analytes due to application of PSA sorbent in a dispersive solid-phase extraction cleanup step. Method LOQs (mLOQs) for five of the six investigated analytes were set at a satisfactory low food product value of 2.5 ng/mL. For DMZ only, the mLOQ was set at 10 ng/mL. The procedure was evaluated through the analysis of 10 different natural samples.
Publisher
Oxford University Press (OUP)
Subject
Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献