Affiliation:
1. Physical Therapy Department, University of Rhode Island
Abstract
The effects of circumferential air-splint pressure on the flexor carpi radialis H-reflex in 22 participants with cerebrovascular accident and 5 with spinal cord injury were examined. H-reflexes were assessed by measuring the peak-to-peak amplitude change before, during, and after circumferential pressure was applied to the forearm. 12 H-reflexes (H/Mmax ratio: M = 25%; SD = 14) were recorded before pressure application to obtain a baseline value for comparison of data. A pneumatic 34-cm air splint inflated to 51–60 mmHg provided pressure around the forearm. H-reflex recordings were taken at 1, 3, and 5 min. during and 1 min. after application of pressure. A one-way analysis of variance with repeated measures was applied to compare pressure and postpressure measurements against the baseline value. Tukey multiple-comparison tests were used when significant F ratios were noted. Analysis indicated H-reflex amplitudes decreased significantly at 1, 3, and 5 min. during pressure and quickly returned to baseline when pressure was released. The study suggests air splints decreased the H-reflex in participants with neurological deficits and may be used in the upper extremity temporarily to reduce muscle activity associated with neurological dysfunction.
Subject
Sensory Systems,Experimental and Cognitive Psychology
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献