Is an Immunoassay Available for the Measurement of Bioactive LH in Serum?

Author:

ROSENFIELD ROBERT L.,HELKE JAMES

Abstract

ABSTRACT: An in vitro bioassay for luteinizing hormone (LH) is in our opinion the “gold standard” bioassay. The rodent interstitial cell testosterone assay (RICT) is specific for bioactive LH and very sensitive, accurate, and reproducible. Diverse LH standards consistently display parallel dose‐response characteristics. Sera also manifest parallel dose‐response characteristics throughout reproductive life, with the exception of basal samples from prepubertal children. This indicates that all known hormones with LH bioactivity have a similar bioactive site. The in vivo bioassays for LH used for calibration of World Health Organization standards are more cumbersome and less precise and accurate than the in vitro bioassay. The ovarian ascorbic acid depletion assay corresponds better than the seminal vesicle weight assay with in vitro bioassay. Variation in the ratio of bioactive to immunoreactive LH (B/I) principally reflects variation in LH immunoassay dose‐response characteristics, rather than a change in the bioactive moiety of LH. The varying B/I ratio is due to molecular heterogeneity at multiple levels. Different LH standards contain different proportions of nonbioactive but immunoreactive material. The immunoreactive LH isoforms in serum contain different proportions of bioactive material and the isoform distribution differs with reproductive status. Furthermore, the antibodies comprising the various immunoassay systems detect heterogeneous epitopes on LH, which are not necessarily bioactive. B/I ratio disparities indicate lack of specificity of immunoassays for bioactive LH. Polyclonal antibody‐based radioimmunoassay requires the use of purified reagents, including a bioactive tracer, in order to achieve high specificity for bioactive LH. The new generation of monoclonal antibody‐based immunometric assays yields results that are lower than, but correlate with, LH measured by the in vitro bioassay. The purest of standards, even a recombinant standard, yields results that differ up to 50% or more from one immunoassay to another. Serum LH levels also differ up to two‐fold among assays. The immunometric assays have the advantage of being more sensitive and more specific for low levels of LH in serum than radio‐immunoassays, but B/I ratio discrepancies remain great. An immunoassay specific for the bioactive “docking site” of human LH isoforms is still needed.

Publisher

Wiley

Subject

Urology,Endocrinology,Reproductive Medicine,Endocrinology, Diabetes and Metabolism

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3