Application of geometric shape‐based CT field‐of‐view extension algorithms in an all‐digital positron emission tomography/computed tomography system

Author:

Hu Tianjiao1,Li Bingxuan2,Yang Jigang3,Zhang Bo4,Fang Lei4,Liu Yuqing2,Xiao Peng124,Xie Qingguo124

Affiliation:

1. Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China

2. Institute of Artificial Intelligence Hefei Comprehensive National Science Center Hefei China

3. Nuclear Medicine Department Beijing Friendship Hospital, Capital Medical University Beijing China

4. Biomedical Engineering Department Huazhong University of Science and Technology Wuhan China

Abstract

AbstractBackgroundComputed tomography (CT)‐based positron emission tomography (PET) attenuation correction (AC) is a commonly used method in PET AC. However, the CT truncation caused by the subject's limbs outside the CT field‐of‐view (FOV) leads to errors in PET AC.PurposeIn order to enhance the quantitative accuracy of PET imaging in the all‐digital DigitMI 930 PET/CT system, we assessed the impact of FOV truncation on its image quality and investigated the effectiveness of geometric shape‐based FOV extension algorithms in this system.MethodsWe implemented two geometric shape‐based FOV extension algorithms. By setting the data from different numbers of detector channels on either side of the sinogram to zero, we simulated various levels of truncation. Specific regions of interest (ROI) were selected, and the mean values of these ROIs were calculated to visually compare the differences between truncated CT, CT extended using the FOV extension algorithms, and the original CT. Furthermore, we conducted statistical analyses on the mean and standard deviation of residual maps between truncated/extended CT and the original CT at different levels of truncation. Subsequently, similar data processing was applied to PET images corrected using original CT and those corrected using simulated truncated and extended CT images. This allowed us to evaluate the influence of FOV truncation on the images produced by the DigitMI 930 PET/CT system and assess the effectiveness of the FOV extension algorithms.ResultsTruncation caused bright artifacts at the CT FOV edge and a slight increase in pixel values within the FOV. When using truncated CT data for PET AC, the PET activity outside the CT FOV decreased, while the extension algorithm effectively reduced these effects. Patient data showed that the activity within the CT FOV decreased by 60% in the truncated image compared to the base image, but this number could be reduced to at least 17.3% after extension.ConclusionThe two geometric shape‐based algorithms effectively eliminate CT truncation artifacts and restore the true distribution of CT shape and PET emission data outside the FOV in the all‐digital DigitMI 930 PET/CT system. These two algorithms can be used as basic solutions for CT FOV extension in all‐digital PET/CT systems.

Funder

National Basic Research Program of China

National Natural Science Foundation of China

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3