Early healing after treatment of coronary lesions by thin strut everolimus, or thicker strut biolimus eluting bioabsorbable polymer stents: The SORT‐OUT VIII OCT study

Author:

Andreasen Lene N.1ORCID,Balleby Ida R.1,Barkholt Trine Ø.1ORCID,Hebsgaard Lasse1,Terkelsen Christian J.1,Holck Emil N.1,Jensen Lisette O.2,Maeng Michael1,Dijkstra Jouke3,Antonsen Lisbeth2,Kristensen Steen D.1,Tu Shengxian4ORCID,Lassen Jens F.2,Christiansen Evald H.1,Holm Niels R.1

Affiliation:

1. Department of Cardiology Aarhus University Hospital Aarhus Denmark

2. Department of Cardiology Odense University Hospital Odense Denmark

3. Division of Image Processing Leiden University Medical Center Leiden The Netherlands

4. Med‐X Research Institute, School of Biomedical Engineering, Biomedical Instrument Institute Shanghai Jiao Tong University Shanghai China

Abstract

AbstractAimsEarly healing after drug‐eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus‐eluting Synergy DES (Boston Scientific) or the biolimus‐eluting Biomatix Neoflex DES (Biosensors).Methods and ResultsA total of 160 patients with the chronic or acute coronary syndrome were randomized 1:1 to Synergy or Biomatrix DES. Optical coherence tomography (OCT) was performed at baseline and at either 1‐ or 3‐month follow‐up. The primary endpoint was a coronary stent healing index (CSHI), a weighted index of strut coverage, neointimal hyperplasia, malapposition, and extrastent lumen. A total of 133 cases had OCT follow‐up and 119 qualified for matched OCT analysis. The median CSHI score did neither differ significantly between the groups at 1 month: Synergy 8.0 (interquartile range [IQR]: 3.0; 14.0) versus Biomatrix 8.5 (IQR: 4.0; 15.0) (p = 0.47) nor at 3 months: Synergy 6.5 (IQR: 2.0; 13.0) versus Biomatrix 6.0 (IQR: 4.0; 11.0) (p = 0.83). Strut coverage was 84.6% (IQR: 72.0; 97.9) for Synergy versus 77.6% (IQR: 70.1; 90.3) for Biomatrix (p = 0.15) at 1 month and 90.3% (IQR 79.0; 98.8) (Synergy) versus 83.9% (IQR: 77.5; 92.6) (Biomatrix) (p = 0.068) at 3 months. Pooled 1‐ and 3‐month coverage was 88.6% (IQR: 74.4; 98.4) for Synergy compared with 80.7% (IQR: 73.2; 90.8) for Biomatrix (p = 0.02).ConclusionsThe early healing response after treatment with the Synergy or Biomatrix DES did not differ significantly as determined by a healing index. The Synergy DES showed overall better early stent strut coverage.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3