Interventional device tracking under MRI via alternating current controlled inhomogeneities

Author:

Uzun Dogangun12ORCID,Yildirim Dursun Korel1ORCID,Bruce Christopher G.1ORCID,Halaby Rim N.1,Jaimes Andrea E.1,Potersnak Amanda1,Ramasawmy Rajiv1,Campbell‐Washburn Adrienne E.1ORCID,Lederman Robert J.1,Kocaturk Ozgur2

Affiliation:

1. Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute National Institutes of Health Bethesda Maryland USA

2. Institute of Biomedical Engineering Bogazici University Istanbul Turkey

Abstract

AbstractPurposeTo introduce alternating current‐controlled, conductive ink‐printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin‐echo sequences.MethodsTracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR‐compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR‐compatible current supply circuit was designed, and the performance of the current‐controlled markers was tested in one postmortem animal experiment using the current supply circuit.ResultsDirection and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom‐designed, 20‐gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit.ConclusionCurrent‐controlled conductive ink‐printed markers can be placed on custom or commercial MR‐compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3