Detecting outliers beyond tolerance limits derived from statistical process control in patient‐specific quality assurance

Author:

Tan Hong Qi12ORCID,Lew Kah Seng13,Wong Yun Ming3,Chong Wen Chuan1,Koh Calvin Wei Yang1,Chua Clifford Ghee Ann1,Yeap Ping Lin1,Ang Khong Wei1,Lee James Cheow Lei13,Park Sung Yong12

Affiliation:

1. Division of Radiation Oncology National Cancer Centre Singapore Singapore Singapore

2. Oncology Academic Clinical Programme Duke‐NUS Medical School Singapore Singapore

3. Division of Physics and Applied Physics Nanyang Technological University Singapore Singapore

Abstract

AbstractBackgroundTolerance limit is defined on pre‐treatment patient specific quality assurance results to identify “out of the norm” dose discrepancy in plan. An out‐of‐tolerance plan during measurement can often cause treatment delays especially if replanning is required. In this study, we aim to develop an outlier detection model to identify out‐of‐tolerance plan early during treatment planning phase to mitigate the above‐mentioned risks.MethodsPatient‐specific quality assurance results with portal dosimetry for stereotactic body radiotherapy measured between January 2020 and December 2021 were used in this study. Data were divided into thorax and pelvis sites and gamma passing rates were recorded using 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria. Statistical process control method was used to determine six different site and criterion‐specific tolerance and action limits. Using only the inliers identified with our determined tolerance limits, we trained three different outlier detection models using the plan complexity metrics extracted from each treatment field—robust covariance, isolation forest, and one class support vector machine. The hyperparameters were optimized using the F1‐score calculated from both the inliers and validation outliers’ data.Results308 pelvis and 200 thorax fields were used in this study. The tolerance (action) limits for 2%/2 mm, 2%/1 mm, and 1%/1 mm gamma criteria in the pelvis site are 99.1% (98.1%), 95.8% (91.1%), and 91.7% (86.1%), respectively. The tolerance (action) limits in the thorax site are 99.0% (98.7%), 97.0% (96.2%), and 91.5% (87.2%). One class support vector machine performs the best among all the algorithms. The best performing model in the thorax (pelvis) site achieves a precision of 0.56 (0.54), recall of 1.0 (1.0), and F1‐score of 0.72 (0.70) when using the 2%/2 mm (2%/1 mm) criterion.ConclusionThe model will help the planner to identify an out‐of‐tolerance plan early so that they can refine the plan further during the planning stage without risking late discovery during measurement.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3