Monte Carlo dosimetry of a novel Yttrium‐90 disc source for episcleral brachytherapy

Author:

Chang Xiangyun12,Huang Lyu2ORCID,Liu Jian3ORCID,Cao Yijian124,Chang Jenghwa124ORCID

Affiliation:

1. MS in Medical Physics Program, Department of Physics and Astronomy Hofstra University Hempstead New York USA

2. Radiation Medicine Northwell Health Lake Success New York USA

3. Radiation Oncology Rhode Island Hospital Providence Rhode Island USA

4. Radiation Medicine Zucker School of Medicine at Hofstra/Northwell Lake Success New York USA

Abstract

AbstractPurposeTo calculate the dose distribution using Monte Carlo simulations for a novel high‐dose‐rate Yttrium‐90 (Y‐90) disc source recently developed for episcleral brachytherapy and provide a lookup table for treatment planning.MethodsMonte Carlo simulations were performed to calculate the in‐water dose distribution of the Y‐90 disc source using the “GATE”, a software based on the “Geant4” Monte Carlo simulation toolkit developed by the international OpenGATE collaboration. The geometry of this novel beta source, its capsule, and the surrounding water medium were accurately modeled in the simulation input files. The standard Y‐90 element beta spectrum from ICRU 72 was used, and the physics processes for beta and photon interactions with matters were all included. The dose distribution of this Y‐90 disc source was measured in a separate study using Gafchromic EBT‐3 films and the results were reported elsewhere. To match the setup of the experiment, a Gafchromic EBT‐3 film was also included in the simulation geometry. The simulated dose profiles were exported from the 3D dose distribution results and compared with the measured dose profiles. Transverse dose profiles at different distances from the seed surface were also obtained to study the lateral coverage of the source.ResultsThe measured percent depth dose (PDD) curves along the central axis perpendicular to the surface of the Y‐90 disc were constructed from the experimental and simulated data, and normalized to the reference point at 1 mm from the source capsule. Both PDD curves agreed well up to 4 mm from the source surface (maximum difference ± 10%) but deviated from each other beyond 4 mm. The deviation might be caused by the increased measurement uncertainty in the low‐dose region. The dose rate at the reference point calculated from the Monte Carlo simulation was 1.09 cGy/mCi‐s and agreed very well with the measured dose rate of 1.05 cGy/mCi‐s. If the 80% isodose line is selected as the lateral coverage, the lateral dose coverage is maximal (∼4.5 mm) at the plane next to the source surface, and gradually decreases with the increasing distance, approaching 3.5 mm when the plane is 5 mm from the 6‐mm diameter source surface.ConclusionMonte Carlo simulations were successfully performed to confirm the measured PDD curve of the novel Y‐90 disc source. This simulation work laid a solid foundation for characterizing the full dosimetry parameters of this source for episcleral brachytherapy applications.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3