Affiliation:
1. Department of Chemistry The University of Akron Akron Ohio USA
2. School of Polymer Science and Polymer Engineering The University of Akron Akron Ohio USA
Abstract
RationaleSimple, affordable, and rapid methods for identifying the molecular weight (MW) distribution and macromolecular composition of polymeric materials are limited. Current tools require extensive solvent consumption, linear calibrations, and expensive consumables. A simple method for the determination of average MW (Mn, Mw) and chain end groups is demonstrated for synthetic homopolymer standards using direct injection electrospray ionization‐mass spectrometry (ESI‐MS) and an open‐sourced charge deconvolution (CDC) algorithm.MethodsFive homopolymer standards in the 1–7 kDa MW range were analyzed using direct‐injection ESI‐MS on a quadrupole/time‐of‐flight mass spectrometer. The samples investigated, viz. two poly(ethylene oxide) (PEO) and two poly(styrene sulfonic acid) (PSS) standards with narrow polydispersity and one poly(d,l‐alanine) (pAla) standard with undefined polydispersity, were chosen to illustrate challenges with ESI‐MS quantitation. Using the UniDec program, weight average MWs (Mw) obtained from the charge‐deconvoluted spectra were compared to the reported Mw data of the standards from size exclusion chromatography (SEC) measurements.ResultsThe MW data derived for the PSS, PEO, and pAla standards agreed well with the corresponding reported Mw or MW range values. The method was able to provide MW, degree of polymerization (DP), and polydispersity index (PDI) information for polymers with narrow (PSS, PEO) as well as broader (pAla) molecular weight distribution; this feature provides an advantage over MW analysis via matrix‐assisted laser desorption/ionization (MALDI) for ESI‐compatible materials. PSS standards differing in average MW by only a few repeat units could be confidently distinguished. Additionally, the oligomeric resolution observed for all samples studied unveiled chain‐end information not available through chromatographic analysis.ConclusionsOverall, the free and easy‐to‐use UniDec CDC algorithm provides a simple, alternative method to measuring MW and DP for polymeric materials without high solvent consumption, expensive ionization sources, or calibration curves. Information about the masses of individual oligomers and the possibility to further characterize these oligomers using tandem mass spectrometry and/or ion mobility techniques constitutes additional benefits of this approach vis‐à‐vis traditional MW and PDI elucidation through SEC.
Funder
National Science Foundation
Subject
Organic Chemistry,Spectroscopy,Analytical Chemistry
Reference44 articles.
1. Correlation of physical and polymer chain properties
2. Electrospray-ion spray: a comparison of mechanisms and performance
3. Calibration of Retention Volume in Size Exclusion Chromatography by Hydrodynamic Radius
4. ClarkeP.Determination of molecular size in polymers and proteins by GPC/SEC. Viscotek Europe Ltd Basingstoke UK 2003.https://alfresco‐static‐files.s3.amazonaws.com/alfresco_images/pharma/2014/08/22/37dCDC11‐be73‐4c30‐8ca5‐2282bd85a066/article‐69531.pdf
5. Characterization of synthetic polymers by MALDI-MS
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献