Affiliation:
1. College of Aerospace and Civil Engineering Harbin Engineering University Harbin China
2. School of Civil Engineering and Transportation Northeast Forestry University Harbin China
3. School of Materials Science and Engineering Southeast University Nanjing China
Abstract
AbstractTo investigate the real anchorage performance of basalt and glass hybrid fiber reinforced plastic (FRP) anchors in external corrosive environments. In this paper, a combination of experimental studies and finite element analysis was used. By carrying out pull‐out tests of basalt and glass hybrid FRP anchors under the synergistic effect of freeze–thaw cycles and alkaline environment, the effects of factors such as hole diameter, anchorage length, and mortar strength on their anchorage performance and durability were investigated. Critical corrosion time was introduced to determine the degree of corrosion of the anchor rods. After that, it combined with numerical simulation to reveal the degradation mechanism of the anchorage performance of hybrid anchors. The results showed that the best anchorage performance of basalt/glass hybrid FRP anchors was achieved when the hole diameter was 24 mm, the anchorage length was 175 mm, and the mortar strength was 45.5 MPa. The ultimate pull‐out load was up to 122.16 kN. When the time did not exceed the critical corrosion time, the ultimate load‐carrying capacity of basalt and glass hybrid FRP anchors increased by 9.3% compared to the uncorroded environment. Beyond the critical corrosion time, the ultimate load‐carrying capacity was reduced by 23.3% and the anchorage performance was degraded. In addition, the contact interface between the anchor and the mortar is the weak area of the anchoring structure, which should be focused on in the later design of the actual project.Highlights
Basalt/glass hybrid FRP anchors have good corrosion resistance.
The anchoring performance of hybrid FRP anchors under the coupled environment is studied.
Hole diameter and anchoring length have more influence on the anchor performance.
The concept of critical corrosion time is put forward.
The failure mechanism and coupling environment influence are revealed by FES.
Funder
Fundamental Research Funds for the Central Universities
National Natural Science Foundation of China
Natural Science Foundation of Heilongjiang Province
Postdoctoral Research Foundation of China
Subject
Materials Chemistry,Polymers and Plastics,General Chemistry,Ceramics and Composites
Reference50 articles.
1. Evaluation of failure risk for prestressed anchor cables based on the AHP-ideal point method: An engineering application
2. Present status and development of ground anchorages;Cheng L;China Civil Eng J,2001
3. HanJ ZhangM ZhangH et al.Rebar bolt optimization for large deformational roadways with application case.2019;48(4):727‐734.
4. PleimannLG.Strength Modulus of Elasticity and Bond of Deformed FRP Rods Advanced Composites Materials in Civil Engineering Structures ASCE 1991 pp. 99–110.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献