Affiliation:
1. Department of Mechanical Engineering Birla Institute of Technology, Mesra Ranchi Jharkhand India
Abstract
AbstractAn exploratory investigation was conducted to analyze a tubular heat exchanger's turbulent heat transfer characteristics using an innovative baffle plate design. The design incorporated a perforated conical baffle plate and an adjustable rectangular deflector. The strategic placement of this baffle plate at the heat exchanger inlet facilitated a swirling flow downstream. To assess the impact of this design, three baffle plates with varying pitch ratios (l/D) were positioned in the direction of the flow. The study examined the effects of pitch ratio (ranging from 0.6 to 1.2), deflector inclination angle (ranging from 30° to 50°), and Reynolds numbers (ranging from 16,500 to 29,500). Moreover, the size of the conical baffle plate (H/D) was altered (from 0.25 to 0.15). The findings highlighted the substantial influence of pitch ratio, inclination angle, and height ratio on the heat exchanger's performance. Notably, the configuration featuring an inclination angle of 50° and height ratio of 0.15 exhibited an average performance improvement of 22% compared to other height ratios, inclination angles, and pitch ratios.
Subject
Fluid Flow and Transfer Processes,Condensed Matter Physics
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献