Design and realization of a multi‐coil array for B0 field control in a compact 1.5T head‐only MRI scanner

Author:

Theilenberg Sebastian1ORCID,Shang Yun1ORCID,Ghazouani Jalal1,Kumaragamage Chathura2ORCID,Nixon Terence W.2,McIntyre Scott2,Vaughan J. Thomas13,Parkinson Ben4ORCID,Garwood Mike5ORCID,de Graaf Robin A.2ORCID,Juchem Christoph13ORCID

Affiliation:

1. Department of Biomedical Engineering Columbia University New York New York USA

2. Department of Radiology and Biomedical Imaging, Magnetic Resonance Research Center Yale University School of Medicine New Haven Connecticut USA

3. Department of Radiology Columbia University Medical Center New York New York USA

4. Robinson Research Institute Victoria University of Wellington Wellington New Zealand

5. Center for Magnetic Resonance Research, Department of Radiology University of Minnesota Minneapolis Minnesota USA

Abstract

PurposeTo design and implement a multi‐coil (MC) array for B0 field generation for image encoding and simultaneous advanced shimming in a novel 1.5T head‐only MRI scanner.MethodsA 31‐channel MC array was designed following the unique constraints of this scanner design: The vertically oriented magnet is very short, stopping shortly above the shoulders of a sitting subject, and includes a window for the subject to see through. Key characteristics of the MC hardware, the B0 field generation capabilities, and thermal behavior, were optimized in simulations prior to its construction. The unit was characterized via bench testing. B0 field generation capabilities were validated on a human 4T MR scanner by analysis of experimental B0 fields and by comparing images for several MRI sequences acquired with the MC array to those acquired with the system's linear gradients.ResultsThe MC system was designed to produce a multitude of linear and nonlinear magnetic fields including linear gradients of up to 10 kHz/cm (23.5 mT/m) with MC currents of 5 A per channel. With water cooling it can be driven with a duty cycle of up to 74% and ramp times of 500 μs. MR imaging experiments encoded with the developed multi‐coil hardware were largely artifact‐free; residual imperfections were predictable, and correctable.ConclusionThe presented compact multi‐coil array is capable of generating image encoding fields with amplitudes and quality comparable to clinical systems at very high duty cycles, while additionally enabling high‐order B0 shimming capabilities and the potential for nonlinear encoding fields.

Funder

National Institute of Biomedical Imaging and Bioengineering

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

Reference61 articles.

1. A portable scanner for magnetic resonance imaging of the brain

2. Lightweight, compact, and high‐performance 3 T MR system for imaging the brain and extremities

3. Low-Cost High-Performance MRI

4. Hyperfine Swoop. Published November 1 2022. Accessed October 31 2022.https://hyperfine.io

5. A compact vertical 1.5T human head scanner with shoulders outside the bore and window for studying motor coordination;Garwood M;Proc Intl Soc Magn Reson Med.,2020

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3