Reducing scan time in 177Lu planar scintigraphy using convolutional neural network: A Monte Carlo simulation study

Author:

Yang Ching‐Ching12,Ko Kuan‐Yin34,Lin Pei‐Yao3

Affiliation:

1. Department of Medical Imaging and Radiological Sciences Kaohsiung Medical University Kaohsiung Taiwan

2. Department of Medical Research Kaohsiung Medical University Chung‐Ho Memorial Hospital Kaohsiung Taiwan

3. Department of Nuclear Medicine National Taiwan University Cancer Center Taipei Taiwan

4. Graduate Institute of Clinical Medicine College of Medicine National Taiwan University Taipei Taiwan

Abstract

AbstractPurposeThe aim of this study was to reduce scan time in 177Lu planar scintigraphy through the use of convolutional neural network (CNN) to facilitate personalized dosimetry for 177Lu‐based peptide receptor radionuclide therapy.MethodsThe CNN model used in this work was based on DenseNet, and the training and testing datasets were generated from Monte Carlo simulation. The CNN input images (IMGinput) consisted of 177Lu planar scintigraphy that contained 10–90% of the total photon counts, while the corresponding full‐count images (IMG100%) were used as the CNN label images. Two‐sample t‐test was conducted to compare the difference in pixel intensities within region of interest between IMG100% and CNN output images (IMGoutput).ResultsNo difference was found in IMGoutput for rods with diameters ranging from 13 to 33 mm in the Derenzo phantom with a target‐to‐background ratio of 20:1, while statistically significant differences were found in IMGoutput for the 10‐mm diameter rods when IMGinput containing 10% to 60% of the total photon counts were denoised. Statistically significant differences were found in IMGoutput for both right and left kidneys in the NCAT phantom when IMGinput containing 10% of the total photon counts were denoised. No statistically significant differences were found in IMGoutput for any other source organs in the NCAT phantom.ConclusionOur results showed that the proposed method can reduce scan time by up to 70% for objects larger than 13 mm, making it a useful tool for personalized dosimetry in 177Lu‐based peptide receptor radionuclide therapy in clinical practice.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3