Abstract

AbstractBackgroundIntensity modulated radiotherapy (IMRT) for head and neck cancer has led to a reduction in radiotherapy doses to normal tissues, like the salivary glands, while maintaining high rates of local control. Oral mucosal and skin toxicity is still a major source of treatment—related morbidity, occurring in most patients.PurposeWe conducted a dosimetric feasibility study with the goal of creating a methodology that could theoretically reduce the dose of radiation to skin and oral mucosa, while maintaining comparable avoidance of other organs at risk, and planning target volume (PTV) coverage.MethodsThe clinical plans of patients treated previously were replanned using coplanar VMAT arcs on a TrueBeam STx using the photon optimizer (PO) version 15.6 and the Acuros XB dose calculation algorithm. Comparisons were made between three methodologies: “Conventional,” “Skin Sparing” and a skin/mucosa avoiding (“SMART”) technique, with dose metrics being compared using analysis of variance, with a Bonferroni correction to account for multiple pairwise comparisons. The maximum grade of mucositis and radiation dermatitis during treatment was correlated to different dose‐volume metrics to predict what could be clinically meaningful.ResultsSixteen patients met the study criteria and were replanned using the skin sparing and SMART techniques. Maximum doses to the skin sparing structure were reduced from 64.2 Gy to 56.6 and 55.9 Gy, in the skin sparing and SMART plans (p < 0.0001), and mean doses reduced from 26.7 Gy to 20.0 and 20.2 Gy, respectively (p < 0.0001). Maximum doses to the oral cavity structure were not reduced by either technique, however mean dose to the oral cavity structure was reduced from 39.03 Gy to 33.5 Gy by the SMART technique (p < 0.0001). There was a slight reduction in PTV_High coverage by the V95% in the SMART plans (99.52% vs. 98.79%, p = 0.0073), and a similar slight reduction in PTV_Low coverage by the V95% by both the skin sparing and SMART plans (99.74% vs. 97.89% vs. 97.42%, p < 0.0001). Maximum doses to organs at risk were not statistically different between techniques. Dose to oral cavity and maximum grade experienced during radiotherapy correlated. The Spearman correlation coefficient for dose to 20%, 50%, and 80% of the volume of oral cavity was 0.5 (p = 0.048), 0.64 (p = 0.007), and 0.62 (p = 0.010), respectively. Skin toxicity grade was only found to be correlated with the D20% of the skin sparing structure (Spearman correlation coefficient of 0.58, p = 0.0177).ConclusionThe SMART technique appears to be able to reduce maximum and mean skin dose, as well as mean oral cavity doses, while only slightly reducing PTV coverage, with acceptable OAR doses. We feel the improvements warrant investigation in a clinical trial.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3