Abstract

AbstractPurposeA multicenter, double‐arm, central core lab, retrospective study was performed to compare the rectal dosimetry of patients implanted with two injectable, biodegradable perirectal spacers, in conventional fractionation (CF), as well as ultrahypofractionation (UH) treatment plans.Methods and materialsFifty‐nine patients were enrolled into the study in five centers: two centers in Europe, which implanted a biodegradable balloon spacer in a total of 24 subjects and three centers in the US, which implanted the SpaceOAR in 35 subjects. Anonymized CTs (pre and post‐implantation) were reviewed by the central core lab. For VMAT CF plans rectal V50, V60, V70, and V80 were calculated. For UH plans, a corresponding rectal V22.6, V27.1, V31.37, and V36.25 were established representing 62.5%, 75%, 87.5%, and 100% of the 36.25 Gy prescribed dose.ResultsFor CF VMAT, a comparison between the balloon spacer and the SpaceOAR revealed a significant difference of 33.4% decrease in mean rectal V50 (71.9% vs. 38.5%, p < 0.001), 27.7% in mean rectal V60 (79.6% vs. 51.9%, p < 0.001), 17.1% difference in mean rectal V70 (84.1% vs. 67.0%, p = 0.001), and a significant difference of 3.0% (p = 0.019) in mean rectal V80 (87.2% vs. 84.2%). With UH analysis, the mean rectal dose reduction for the balloon spacer compared to the SpaceOAR was 79.2% and 53.3% for V27.1 (p < 0.001), 84.1% and 68.1% for V31.71 (p = 0.001), and 89.7% and 84.8% for V36.25 (p = 0.012), respectively.ConclusionRectal dosimetry is more favorable for treatment with the balloon spacer compared with SpaceOAR. Further research, particularly in the context of a prospective randomized clinical trial design, is needed to assess the acute and late toxicity experience as well as physician satisfaction with achieving symmetrical implantation, and ease of use in light of increasing clinical use.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3