Impact of storage temperature and filtration method on dissolved trace metal concentrations in coastal water samples

Author:

Przibilla Anna12ORCID,Iwainski Susanna13,Zimmermann Tristan1,Pröfrock Daniel1

Affiliation:

1. Institute of Coastal Environmental Chemistry/Department Inorganic Environmental Chemistry Helmholtz‐Zentrum Hereon Geesthacht Germany

2. Department of Chemistry, Institute for Inorganic and Applied Chemistry Universität Hamburg Hamburg Germany

3. Faculty of Chemistry and Biotechnology Fachhochschule Aachen (Campus Jülich) Jülich Germany

Abstract

AbstractTrace elements play a major role in biogeochemical cycles and oceanographic processes. To determine trace element concentrations, the dissolved and particulate phase are usually separated by filtration. However, the frequently used membrane filtration as well as sample storage can bias the dissolved elemental concentrations by adsorption or desorption/contamination. We present a comparison of two filtration methods for coastal and estuarine water samples (pressure filtration with Nuclepore™ polycarbonate filters, vacuum filtration with DigiFILTER™s) applied to aliquots of a large‐volume coastal water sample that were stored at −18°C or 4°C for up to nine weeks. The filtrates were analyzed by seaFAST‐ICP‐MS for dissolved Cd, Ce, Co, Cu, Dy, Er, Eu, Fe, Ho, La, Mn, Mo, Nd, Pb, Pr, Sm, Tb, U, V, W, Y, and Zn. The filtration blanks of DigiFILTER™s (0.0006 ± 0.0010 ng L−1 for Ho to 110 ± 180 ng L−1 for Zn) were sufficiently low for quantification of all analyzed elements with good repeatability, enabling a fast and reliable filtration of large sample sets of coastal water. However, the findings also highlight the need to measure procedural blanks including the filtration instead of only the instrument blanks to validate results. Measured concentrations of both filtration methods did not differ significantly for Cd, Cu, Mo, U, V, W, Zn but for other investigated elements, the ratio between both methods was up to 1.8 for Ce and 4.1 for Fe. Within nine weeks of storage, the elemental concentrations decreased significantly, resulting in losses of 20% Mn in frozen samples and 63% Pb, 64% Co and 93% Mn in cooled samples.Practitioner Points Two fast and cheap filtration methods for coastal water samples were compared. Dissolved concentrations of 22 elements were measured by seaFAST‐ICP‐MS. The filtration method is important in addition to filter pore size. Filtration blanks need to be reported to maintain comparability between methods. Cool and frozen storage of water samples biases the dissolved metal concentration.

Funder

Bundesministerium für Bildung und Forschung

Publisher

Wiley

Subject

Water Science and Technology,Ecological Modeling,Waste Management and Disposal,Pollution,Environmental Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3