AAPM Task Group Report 261: Comprehensive quality control methodology and management of dental and maxillofacial cone beam computed tomography (CBCT) systems

Author:

Mihailidis Dimitris N.1,Stratis Andreas2,Gingold Eric3,Carlson Ray4,DeForest William5,Gray Joel6,Lally Mary T.7,Pizzutiello Robert8,Rong John9,Spelic David10,Hilohi Mike C.10,Massoth Richard11

Affiliation:

1. University of Pennsylvania, Perelman Center for Advanced Medicine Philadelphia Pennsylvania USA

2. Katholieke Universiteit Leuven Leuven Belgium

3. Department of Radiology Thomas Jefferson University Philadelphia Pennsylvania USA

4. Radiological Physics Services, Inc Plymouth Michigan USA

5. Landauer Medical Physics Cary North Carolina USA

6. Diquad, LLC Steger Illinois USA

7. Intersocietal Accreditation Commission Ellicott City Maryland USA

8. Upstate Medical Physics, PC Victor New York USA

9. Department of Imaging Physics UT MD Anderson Cancer Center Houston Texas USA

10. Food and Drug Administration Center for Device and Radiological Health Silver Spring Maryland USA

11. Sunflower Medical Physics, LLC Sioux Falls South Dakota USA

Abstract

AbstractCone‐beam computed tomography (CBCT) systems specifically designed and manufactured for dental, maxillofacial imaging (MFI) and otolaryngology (OLR) applications have been commercially available in the United States since 2001 and have been in widespread clinical use since. Until recently, there has been a lack of professional guidance available for medical physicists about how to assess and evaluate the performance of these systems and about the establishment and management of quality control (QC) programs. The owners and users of dental CBCT systems may have only a rudimentary understanding of this technology, including how it differs from conventional multidetector CT (MDCT) in terms of acceptable radiation safety practices. Dental CBCT systems differ from MDCT in several ways and these differences are described. This report provides guidance to medical physicists and serves as a basis for stakeholders to make informed decisions regarding how to manage and develop a QC program for dental CBCT systems. It is important that a medical physicist with experience in dental CBCT serves as a resource on this technology and the associated radiation protection best practices. The medical physicist should be involved at the pre‐installation stage to ensure that a CBCT room configuration allows for a safe and efficient workflow and that structural shielding, if needed, is designed into the architectural plans. Acceptance testing of new installations should include assessment of mechanical alignment of patient positioning lasers and x‐ray beam collimation and benchmarking of essential image quality performance parameters such as image uniformity, noise, contrast‐to‐noise ratio (CNR), spatial resolution, and artifacts. Several approaches for quantifying radiation output from these systems are described, including simply measuring the incident air‐kerma (Kair) at the entrance surface of the image receptor. These measurements are to be repeated at least annually as part of routine QC by the medical physicist. QC programs for dental CBCT, at least in the United States, are often driven by state regulations, accreditation program requirements, or manufacturer recommendations.

Publisher

Wiley

Subject

General Medicine

Reference84 articles.

1. Global dental X‐ray System Market 2019 by Manufacturers Regions Type and Application Forecast to 2024. Global Dental X Ray System Market—Industry Reports. industryresearch.biz.

2. Application of Limited Cone Beam Computed Tomography to Clinical Assessment of Alveolar Bone Grafting: A Preliminary Report

3. Clinical application of cone beam digital volume tomography in children with cleft lip and palate

4. Value of Two Cone-beam Computed Tomography Systems from an Orthodontic Point of View

5. Quantitative evaluation with CBCT of palatal bone thickness in growing patients;Gracco A;Prog Orthod,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3