Three‐dimensional echo‐shifted EPI with simultaneous blip‐up and blip‐down acquisitions for correcting geometric distortion

Author:

Sun Kaibao1ORCID,Chen Zhifeng23,Dan Guangyu14ORCID,Luo Qingfei1ORCID,Yan Lirong25,Liu Feng6,Zhou Xiaohong Joe147ORCID

Affiliation:

1. Center for Magnetic Resonance Research University of Illinois at Chicago Chicago Illinois USA

2. Keck School of Medicine USC Stevens Neuroimaging and Informatics Institute, University of Southern California Los Angeles California USA

3. Department of Data Science and AI, Faculty of IT Monash University Clayton Victoria Australia

4. Department of Biomedical Engineering University of Illinois at Chicago Chicago Illinois USA

5. Department of Radiology, Feinberg School of Medicine Northwestern University Chicago Illinois USA

6. School of Information Technology and Electrical Engineering The University of Queensland Brisbane Queensland Australia

7. Departments of Radiology and Neurosurgery University of Illinois at Chicago Chicago Illinois USA

Abstract

AbstractPurposeEPI with blip‐up/down acquisition (BUDA) can provide high‐quality images with minimal distortions by using two readout trains with opposing phase‐encoding gradients. Because of the need for two separate acquisitions, BUDA doubles the scan time and degrades the temporal resolution when compared to single‐shot EPI, presenting a major challenge for many applications, particularly fMRI. This study aims at overcoming this challenge by developing an echo‐shifted EPI BUDA (esEPI‐BUDA) technique to acquire both blip‐up and blip‐down datasets in a single shot.MethodsA 3D esEPI‐BUDA pulse sequence was designed by using an echo‐shifting strategy to produce two EPI readout trains. These readout trains produced a pair of k‐space datasets whose k‐space trajectories were interleaved with opposite phase‐encoding gradient directions. The two k‐space datasets were separately reconstructed using a 3D SENSE algorithm, from which time‐resolved B0‐field maps were derived using TOPUP in FSL and then input into a forward model of joint parallel imaging reconstruction to correct for geometric distortion. In addition, Hankel structured low‐rank constraint was incorporated into the reconstruction framework to improve image quality by mitigating the phase errors between the two interleaved k‐space datasets.ResultsThe 3D esEPI‐BUDA technique was demonstrated in a phantom and an fMRI study on healthy human subjects. Geometric distortions were effectively corrected in both phantom and human brain images. In the fMRI study, the visual activation volumes and their BOLD responses were comparable to those from conventional 3D echo‐planar images.ConclusionThe improved imaging efficiency and dynamic distortion correction capability afforded by 3D esEPI‐BUDA are expected to benefit many EPI applications.

Funder

National Institutes of Health

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3