Technical note: Cryostat transmission characterization for MR linac – temporal stability, clinical impact and change implementation

Author:

Jelen Urszula1ORCID,Pagulayan Claire1,Moutrie Zoë234,Arts Jason5,George Armia5,Jameson Michael G.167

Affiliation:

1. GenesisCare Alexandria NSW Australia

2. South Western Sydney Cancer Services New South Wales Health Liverpool NSW Australia

3. South West Sydney Clinical Campuses University of New South Wales Warwick Farm NSW Australia

4. Ingham Institute for Applied Medical Research Liverpool NSW Australia

5. Elekta Pty Ltd North Sydney NSW Australia

6. University of New South Wales Sydney NSW Australia

7. University of Wollongong Wollongong NSW Australia

Abstract

AbstractBackgroundIn the Unity MR linac (Elekta AB, Stockholm, Sweden), the radiation beam traverses the cryostat and the coil support structure. The resulting beam attenuation must be considered for output calibration and its variation with gantry angle must be characterized in the treatment planning system (TPS).PurposeThe aim of this work was to investigate the impact of a change of the cryostat transmission characterization (CTC) curve, due to the helium level modification, on clinical treatment plan dosimetry and to report on the experience with the CTC curve update.MethodsTwenty stereotactic body radiotherapy (SBRT) treatment plans: 10 prostate and 10 oligo‐metastatic cancer plans, prepared with a beam model incorporating the CTC curve acquired at installation time, were re‐calculated using the model implementing CTC curve post helium top‐up. To account for the CTC change as well as to align our system to the recent reference conditions recommendations, the new model was commissioned with the emphasis on the specifics associated with the treatment plan adaptation and the existence of the offline and online TPS components.ResultsAverage CTV mean dose reduction by 0.45% in prostate cases and average GTV mean dose reduction by 0.22% in oligo‐metastatic cases was observed. Updated model validation showcased good agreement between measurements and TPS calculations.ConclusionsThe agreement between CTC measurements demonstrates its temporal constancy and robustness of the measurement method employed. A helium fill level change was shown to affect the CTC and led to a small but systematic dose calculation inaccuracy. Finally, model validation and end‐to‐end testing results presented, underscore the minimal impact of transitioning to the new beam model and new reference conditions.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3