A novel artificial intelligence model for measuring fetal intracranial markers during the first trimester based on two‐dimensional ultrasound image

Author:

Sun Lingling1ORCID,Yu Junxuan2,Yao Jiezhi2ORCID,Cao Yan3,Sun Naimin1,Chen Keqi1,Lin Yujia2,Ji Chunya1,Zhang Jun1,Ling Chen1,Yang Zhong1,Pan Qi1,Yang Ronghao2,Yang Xin2,Ni Dong2,Yin Linliang1,Deng Xuedong1

Affiliation:

1. Center for Medical Ultrasound The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University Suzhou Jiangsu China

2. National‐Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Health Science Center Shenzhen University Shenzhen Guangdong China

3. Shenzhen RayShape Medical Technology Co., Ltd Shenzhen Guangdong China

Abstract

AbstractObjectiveTo establish reference ranges of fetal intracranial markers during the first trimester and develop the first novel artificial intelligence (AI) model to measure key markers automatically.MethodsThis retrospective study used two‐dimensional (2D) ultrasound images from 4233 singleton normal fetuses scanned at 11+0–13+6 weeks of gestation at the Affiliated Suzhou Hospital of Nanjing Medical University from January 2018 to July 2022. We analyzed 10 key markers in three important planes of the fetal head. Based on these, reference ranges of 10 fetal intracranial markers were established and an AI model was developed for automated marker measurement. AI and manual measurements were compared to evaluate differences, correlations, consistency, and time consumption based on mean error, Pearson correlation analysis, intraclass correlation coefficients (ICCs), and average measurement time.ResultsThe results of AI and manual methods had strong consistency and correlation (all ICC values >0.75, all r values >0.75, and all P values <0.001). The average absolute error of both only ranged from 0.124 to 0.178 mm. AI achieved a 100% detection rate for abnormal cases. Additionally, the average measurement time of AI was only 0.49 s, which was more than 65 times faster than the manual measurement method.ConclusionThe present study first established the normal standard reference ranges of fetal intracranial markers based on a large Chinese population data set. Furthermore, the proposed AI model demonstrated its capability to measure multiple fetal intracranial markers automatically, serving as a highly effective tool to streamline sonographer tasks and mitigate manual measurement errors, which can be generalized to first‐trimester scanning.

Funder

Science and Technology Planning Project of Guangdong Province

National Natural Science Foundation of China

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3