Whole knee joint mapping using a phase modulated UTE adiabatic T (PM‐UTE‐AdiabT) sequence

Author:

Ma Yajun1,Carl Michael2,Tang Qingbo13,Moazamian Dina1,Athertya Jiyo S.1,Jang Hyungseok1ORCID,Bukata Susan V.4,Chung Christine B.13,Chang Eric Y.13,Du Jiang135

Affiliation:

1. Department of Radiology University of California, San Diego San Diego California USA

2. GE Healthcare San Diego California USA

3. Radiology Service Veterans Affairs San Diego Healthcare System San Diego California USA

4. Department of Orthopaedic Surgery University of California, San Diego San Diego California USA

5. Department of Bioengineering University of California, San Diego San Diego California USA

Abstract

AbstractPurposeTo develop a 3D phase modulated UTE adiabatic T (PM‐UTE‐AdiabT) sequence for whole knee joint mapping on a clinical 3 T scanner.MethodsThis new sequence includes six major features: (1) a magnetization reset module, (2) a train of adiabatic full passage pulses for spin locking, (3) a phase modulation scheme (i.e., RF cycling pair), (4) a fat saturation module, (5) a variable flip angle scheme, and (6) a 3D UTE Cones sequence for data acquisition. A simple exponential fitting was used for T quantification. Phantom studies were performed to investigate PM‐UTE‐AdiabT's sensitivity to compositional changes and reproducibility as well as its correlation with continuous wave–T measurement. The PM‐UTE‐AdiabT technique was then applied to five ex vivo and five in vivo normal knees to measure T values of femoral cartilage, meniscus, posterior cruciate ligament, anterior cruciate ligament, patellar tendon, and muscle.ResultsThe phantom study demonstrated PM‐UTE‐AdiabT's high sensitivity to compositional changes, its high reproducibility, and its strong linear correlation with continuous wave–T measurement. The ex vivo and in vivo knee studies demonstrated average T values of 105.6 ± 8.4 and 77.9 ± 3.9 ms for the femoral cartilage, 39.2 ± 5.1 and 30.1 ± 2.2 ms for the meniscus, 51.6 ± 5.3 and 29.2 ± 2.4 ms for the posterior cruciate ligament, 79.0 ± 9.3 and 52.0 ± 3.1 ms for the anterior cruciate ligament, 19.8 ± 4.5 and 17.0 ± 1.8 ms for the patellar tendon, and 91.1 ± 8.8 and 57.6 ± 2.8 ms for the muscle, respectively.ConclusionThe 3D PM‐UTE‐AdiabT sequence allows volumetric T assessment for both short and long T2 tissues in the knee joint on a clinical 3 T scanner.

Funder

GE Healthcare

National Institutes of Health

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3