Abstract

AbstractIncreased chromium usage in industrial applications as chromium III and chromium VI, include metal plating, steel alloys, leather processing, medical applications, and chromium dyeing operations, has resulted in water pollution by Cr (VI) ions, which being toxic and carcinogenic has developed into significant environmental and health problems. The purpose of this research is to remove Cr (VI) ions from synthetic wastewater utilising modified sawdust as an inexpensive adsorbent. Two modified sawdust samples were produced, one using sodium hydroxide and one using sulfuric acid. The experimentation, based on several batch systems, has been undertaken at 25–65°C with 0.5–1.5 g/L sawdust dosage. These conditions were applied to remove Cr (VI) ions at concentrations of 1–6 ppm at pH values from 3 to 10. The results have shown that adsorption onto sawdust followed an intraparticle diffusion mechanism with various rate parameters from 0.65 to 5.24 mg g−1 min, for treated and untreated sawdust. The distribution coefficient , enthalpy , thermodynamic standard free energy , and entropy were determined from a number of temperature studies. Kinetic studies showed that the pseudo‐second order model gave the optimum correlation to the experimental results. The Freundlich and Langmuir isotherms were applied to analyse the experimental equilibrium results. The optimised conditions for the adsorption process were obtained using the D‐optimal design method, and the maximum removal percentage of 100%, was determined at pH = 3, T = 25°C, adsorbent dosage = 1.5 g/L, and an initial Cr (VI) concentration = 5.72 ppm.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3