Can lung ultrasound score accurately predict surfactant replacement? A systematic review and meta‐analysis of diagnostic test studies

Author:

Capasso Letizia1ORCID,Pacella Daniela2,Migliaro Fiorella1,Salomè Serena1ORCID,Grasso Fiorentino1,Corsini Iuri3ORCID,De Luca Daniele4ORCID,Davis Peter G.5,Raimondi Francesco1

Affiliation:

1. Division of Neonatology, Department of Translational Medical Sciences Università Federico II di Napoli Naples Italy

2. Department of Public Health Università Federico II di Napoli Naples Italy

3. Careggi Hospital Università di Firenze Florence Italy

4. Service de Pediatrie et Reanimation Neonatale Hopital “A. Beclere”—Paris Saclay University Hospitals, APHP Paris France

5. Newborn Research Centre, The Royal Women's Hospital University of Melbourne Parkville Victoria Australia

Abstract

AbstractBackgroundClinical and radiographic criteria are traditionally used to determine the need for surfactant therapy in preterm infants. Lung ultrasound is a bedside test that offers a rapid, radiation‐free, alternative to this approach.ObjectiveTo conduct a systematic review and meta‐analysis to determine the accuracy of a lung ultrasound score (LUS) in identifying infants who would receive at least one surfactant dose. Secondary aims were to evaluate the predictive accuracy for ≥2 doses and the accuracy of a different image classification system based on three lung ultrasound profiles.MethodsPubMed, SCOPUS, Biomed Central, and the Cochrane library between January 2011 and December 2021 were searched. Full articles enrolling preterm neonates who underwent lung ultrasound to predict surfactant administration were assessed and analyzed following Preferred Reporting Items for Systematic Review and Meta‐Analysis Protocols (PRISMA‐P) and QUADAS‐2 guidelines.ResultsSeven prospective studies recruiting 697 infants met the inclusion criteria. Risk of bias was generally low. Oxygen requirement, clinical and radiographic signs of respiratory distress syndrome were used as reference standards for surfactant replacement. The summary receiver operator characteristic (sROC) curve for LUS predicting first surfactant dose showed an area under the curve (AUC) = 0.88 (95% confidence interval [CI]: 0.82–0.91); optimal specificity and sensitivity (Youden index) were 0.83 and 0.81 respectively. Pooled estimates of sensitivity, specificity, diagnostic odds ratio, negative predictive value, and positive predictive value for LUS predicting the first surfactant dose were 0.89 (0.82–0.95), 0.86 (0.78–0.95), 3.78 (3.05–4.50), 0.92 (0.87–0.97), 0.79 (0.65–0.92). The sROC curve for the accuracy of Type 1 lung profile in predicting first surfactant dose showed an AUC of 0.88; optimal specificity and sensitivity were both 0.86. Two studies addressing the predictive accuracy of LUS for ≥2 surfactant doses had high heterogeneity and were unsuitable to combine in a meta‐analysis.DiscussionDespite current significant variation in LUS thresholds, lung ultrasound is highly predictive of the need for early surfactant replacement. This evidence was derived from studies with homogeneous patient characteristics and low risk of bias.

Publisher

Wiley

Subject

Pulmonary and Respiratory Medicine,Pediatrics, Perinatology and Child Health

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3