Spatially and velocity‐selective magnetization preparation for noncontrast‐enhanced peripheral MR angiography

Author:

Shin Taehoon12ORCID,Lee Hyun‐Soo3,Zun Zungho4ORCID,Jang Jinhee5

Affiliation:

1. Division of Mechanical and Biomedical Engineering Ewha Womans University Seoul South Korea

2. Graduate Program in Smart Factory Ewha Womans University Seoul South Korea

3. Siemens Healthineers Ltd Seoul South Korea

4. Department of Radiology Weill Cornell Medicine New York New York USA

5. Department of Radiology, Seoul St. Mary's Hospital College of Medicine, The Catholic University of Korea Seoul South Korea

Abstract

AbstractThe purpose of the current study was to develop spatially and velocity‐selective (SVS) magnetization preparation pulses for noncontrast‐enhanced peripheral MR angiography (MRA) to provide comparisons with velocity‐selective (VS) MRA with comparison to velocity‐selective (VS). VS preparation pulses were designed by concatenating multiple excitation steps, each of which was a combination of a hard RF pulse, VS unipolar gradient pulses, and refocusing RF pulses. SVS preparation pulses were designed by replacing the hard RF pulse with a sinc‐shaped RF pulse combined with a symmetric tripolar gradient pulse (which does not perturb the velocity encoding by the VS unipolar gradient pulses). Numerical simulations were performed to verify the intended hybrid excitation selectivity of SVS pulses taking account of tissue relaxation, magnetic field errors, and eddy currents. In vivo experiments were performed in healthy subjects to verify the hybrid excitation selectivity, as well as to demonstrate the visualization of the entire peripheral arteries using six‐station protocols. As demonstrated by numerical simulations, SVS preparation yielded a notch‐shaped longitudinal magnetization (Mz)‐velocity response within the spatial stopband (the same as VS preparation) and preserved the Mz of spins outside the stopband, regardless of its velocity. We confirmed these observations also through in vivo tests with good agreement in normalized arterial and muscle signal intensities. In six‐station peripheral MRA experiments, the proposed SVS‐MRA yielded significantly higher arterial signal‐to‐noise ratio (SNR) (51.6 ± 14.3 vs. 38.9 ± 10.9; p < 0.001) and contrast‐to‐noise ratio (CNR) (41.2 ± 13.0 vs. 31.3 ± 10.5; p < 0.001) compared with VS‐MRA. The proposed SVS‐MRA improves arterial SNR and CNR compared with VS‐MRA by mitigating undesired presaturation of arterial blood upstream the imaging field of view.

Funder

National Research Foundation of Korea

Publisher

Wiley

Subject

Spectroscopy,Radiology, Nuclear Medicine and imaging,Molecular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3