Proposal for vertical distribution of seismic design load and equivalent isolation ratio for seismically isolated buildings with multiple types of dampers: Vertical distribution of seismic design load for seismically isolated buildings corresponding to diversity of seismic isolation devices, part 2
-
Published:2023-12-10
Issue:1
Volume:7
Page:
-
ISSN:2475-8876
-
Container-title:JAPAN ARCHITECTURAL REVIEW
-
language:en
-
Short-container-title:Japan Architectural Review
Author:
Kobayashi Masahito1ORCID,
Komachi Yusuke2
Affiliation:
1. Department of Architecture, School of Science and Technology Meiji University Kawasaki‐shi Japan
2. Structural Design Department Toda Corporation Tokyo Japan
Abstract
AbstractAs previously reported, we have proposed a vertical distribution of seismic design load for seismically isolated buildings (SIBs) corresponding to diversity of seismic isolation devices such as hysteretic dampers and velocity‐dependent dampers. This proposed seismic design load is obtained from the relationship between response amplification caused by higher mode responses and the isolation ratio which represents structural characteristics of SIBs. In this paper, we build a concept of the equivalent isolation ratio which has applicability to various dampers in order to simplify an evaluation formula of vertical distribution of seismic design load. Moreover, an effect of the combined application of various dampers on vertical distribution of shear force coefficient of SIBs is analyzed on the basis of the equivalent isolation ratio.
Funder
Japan Society for the Promotion of Science
Subject
Modeling and Simulation,Architecture,Environmental Engineering
Reference15 articles.
1. Ministry of Land Infrastructure Transport and Tourism Housing Bureau Guidance Division etc. Edition. Menshinkenchikubutsu no Gijutsukijunkaisetsu Oyobi Keisanrei to Sonokaisetsu (Commentary on technical standards for seismically isolated buildings calculation examples and their explanations).2001. (in Japanese).
2. IibaM TamuraK SarutaM et al.Evaluation on distribution of story shear coefficient for structural design of seismically isolated building. Building Research Data No. 162 2014.8 (in Japanese)https://www.kenken.go.jp/japanese/contents/publications/data/162/index.html
3. Japan Society of Seismic Isolation.Menshinbuzai‐hyoujunhin list (list of standard seismic isolation devices 2009). 2009. (in Japanese).