Spectral information content of Compton scattering events in silicon photon counting detectors

Author:

Hsieh Scott S.1,Taguchi Katsuyuki2

Affiliation:

1. Department of Radiology Mayo Clinic Rochester Minnesota USA

2. Departments of Radiology and Bioengineering Johns Hopkins University Baltimore Maryland USA

Abstract

AbstractBackgroundSilicon (Si) is a possible sensor material for photon counting detectors (PCDs). A major drawback of Si is that roughly two‐thirds of x‐ray interactions in the diagnostic energy range are Compton scattering. Because Compton scattering is an energy‐insensitive process, it is commonly assumed that Compton events retain little spectral information.PurposeTo quantify how much information can be recovered from Compton scattering events in models of Si PCDs.MethodsWe built a simplified model of Si interactions including two interaction mechanisms: photoelectric effect and Compton scattering. We considered three different binning options that represent strategies for handling Compton events: in Compton censoring, all events under 38 keV (the maximum energy possible from Compton scattering for a 120 keV incident photon) were discarded; in Compton counting, all events between 1 and 38 keV were placed into a single bin; in Compton binning, all events were placed into energy bins of uniform width. These were compared to the ideal detector, which always recorded the correct energy (i.e., 100% photoelectric effect). Every photon was assumed to interact once and only once with Si, and the energy bin width was 5 keV. In the primary analysis, the Si detector was irradiated with a 120 kV spectrum filtered by 30 cm of water, with 99.5% of the arriving spectrum above 38 keV so that there was good separation between photoelectric effect and Compton scattering, and the figures of merit were the CramérRao lower bound (CRLB) of the variance of iodine and water basis material decomposition images, as well as the CRLB of virtual monoenergetic images (i.e., linear combinations of material images) that maximize iodine CNR or water CNR. We also constructed a local linear estimator that attains the CRLB. In secondary analyses, we applied other sources of spectral distortion: (1) a nonzero minimum energy threshold; (2) coarser, 10 keV energy bins; and (3) a model of charge sharing.ResultsWith our chosen spectrum, 67% of the interactions were Compton scattering. Consistent with this, the material decomposition variance for the Compton censoring model, averaged over both basis materials, was 258% greater than the ideal detector. If Compton events carried no spectral information, the Compton counting model would show similar variance. Instead, its basis material variance was 103% greater than the ideal detector, implying that Compton counts indeed carry significant spectral information. The Compton binning model had a basis material variance 60% greater than the ideal detector. The Compton binning model was not affected by a 5 keV minimum energy threshold, but the variance increased from 60% to 107% when charge sharing was included and to 78% with coarser energy bins. For optimized CNR images, the average variance was 149%, 12%, and 10% higher than the ideal detector for the Compton censoring, counting, and binning models, reinforcing the hypothesis that Compton counts are useful for detection tasks and that precise energy assignments are not necessary.ConclusionsSubstantial spectral information remains after Compton scattering events in silicon PCDs.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3