Dispersive solid phase extraction of metronidazole and clarithromycin from human plasma using a β‐cyclodextrin grafted polyethylene polymer composite

Author:

Javanbakht Faezeh12,Afshar Mogaddam Mohammad Reza34ORCID,Nemati Mahboob23ORCID,Farajzadeh Mir Ali56ORCID

Affiliation:

1. Student Research Committee Tabriz University of Medical Sciences Tabriz Iran

2. Pharmaceutical and Food Control Department Tabriz University of Medical Sciences Tabriz Iran

3. Food and Drug Safety Research Center Tabriz University of Medical Sciences Tabriz Iran

4. Pharmaceutical Analysis Research Center Tabriz University of Medical Sciences Tabriz Iran

5. Department of Analytical Chemistry Faculty of Chemistry University of Tabriz Tabriz Iran

6. Engineering Faculty Near East University Nicosia Turkey

Abstract

In this work, for the first time, a polymeric composite based on β‐cyclodextrin grafted with polyethylene has been prepared through ball milling and used as an efficient sorbent for dispersive solid phase extraction of metronidazole and clarithromycin from plasma samples. The prepared sorbent was characterized using Fourier transform infrared spectrophotometry, X‐ray diffraction, and scanning electron microscopy. In the extraction process, after precipitating the proteins, the sorbent was added into the sample solution, and the mixture was vortexed to facilitate and speed up the sorption of the analytes onto the sorbent surface. After centrifuging, the sorbent particles were contacted with methanol to elute the analytes under the vortexing process. After this step, an aliquot of the eluate was taken and injected into high‐performance liquid chromatography–diode array detector for quantitative analysis. Under the optimum extraction conditions, the extraction recoveries for metronidazole and clarithromycin were 76 and 83%, respectively. The limits of detection were 2.6 and 2.2 ng/ml for metronidazole and clarithromycin, respectively. The repeatability of the offered approach, expressed as relative standard deviation, was equal to or less than 4.7%. Finally, the method was successfully applied to plasma samples of the patients treated with metronidazole and clarithromycin.

Publisher

Wiley

Subject

Filtration and Separation,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3