Affiliation:
1. Department of Biotechnology Institute for Biochemistry University of Applied Sciences Mannheim Germany
2. CMC Microbial Platform Sanofi‐Aventis Deutschland GmbH Frankfurt am Main Germany
3. IA MSAT M&I DS Sanofi‐Aventis Deutschland GmbH Frankfurt am Main Germany
Abstract
In process development and characterization, the scale‐up of chromatographic steps is a crucial part and brings a number of challenges. Usually, scale‐down models are used to represent the process step, and constant column properties are assumed. The scaling is then typically based on the concept of linear scale‐up. In this work, a mechanistic model describing an anti‐Langmuirian to Langmuirian elution behavior of a polypeptide, calibrated with a pre‐packed 1 ml column, is applied to demonstrate the scalability to larger column volumes up to 28.2 ml. Using individual column parameters for each column size, scaling to similar eluting salt concentrations, peak heights, and shapes is experimentally demonstrated by considering the model's relationship between the normalized gradient slope and the eluting salt concentration. Further scale‐up simulations show improved model predictions when radial inhomogeneities in packing quality are considered.
Subject
Filtration and Separation,Analytical Chemistry
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献