A generalized QUCESOP method with evaluating CEST peak overlap

Author:

Wang Yi1,Sun Yi‐Xuan2,Yang Qiu‐Yu1,Gao Jia‐Hong3456

Affiliation:

1. Public Health Science and Engineering College Tianjin University of Traditional Chinese Medicine Tianjin China

2. School of Medical Technology Tianjin University of Traditional Chinese Medicine Tianjin China

3. Center for MRI Research, Academy for Advanced Interdisciplinary Studies Peking University Beijing China

4. Beijing City Key Lab for Medical Physics and Engineering, Institute of Heavy Ion Physics, School of Physics Peking University Beijing China

5. McGovern Institute for Brain Research Peking University Beijing China

6. National Biomedical Imaging Center Peking University Beijing China

Abstract

AbstractThe overlapping peaks of the target chemical exchange saturation transfer (CEST) solutes and other unknown CEST solutes affect the quantification results and accuracy of the chemical exchange parameters—the fractional concentration, , exchange rate, , and transverse relaxation rate, —for the target solutes. However, to date, no method has been established for assessing the overlapping peaks. This study aimed to develop a method for quantifying the , , and values of a specific CEST solute, as well as assessing the overlap between the CEST peaks of the specific solute(s) and other unknown solutes. A simplified model was proposed, assuming linear approximation of the other solutes' contributions to . A CEST data acquisition scheme was applied with various saturation offsets and saturation powers. In addition to fitting the , , and values of the specific solute, the overlapping condition was evaluated based on the root mean square error (RMSE) between the trajectories of the acquired and synthesized data. Single‐solute and multi‐solute phantoms with various phosphocreatine (PCr) concentrations and pH values were used to calculate the and of PCr and the corresponding RMSE. The feasibility of RMSE for evaluating the overlapping condition, and the accurate fitting of and in weak overlapping conditions, were verified. Furthermore, the method was employed to quantify the nuclear Overhauser effect signal in rat brains and the PCr signal in rat skeletal muscles, providing results that were consistent with those reported in previous studies. In summary, the proposed approach can be applied to evaluate the overlapping condition of CEST peaks and quantify the , , and values of specific solutes, if the weak overlapping condition is satisfied.

Funder

National Natural Science Foundation of China

Publisher

Wiley

Subject

Spectroscopy,Radiology, Nuclear Medicine and imaging,Molecular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3