Experimental measurement of local noise power spectrum (NPS) in photon counting detector‐CT (PCD‐CT) using a single data acquisition

Author:

Zhang Chengzhu1,Li Ke12,Zhang Ran1,Chen Guang‐Hong12

Affiliation:

1. Department of Medical Physics University of Wisconsin School of Medicine and Public Health Madison Wisconsin USA

2. Department of Radiology University of Wisconsin School of Medicine and Public Health Madison Wisconsin USA

Abstract

AbstractBackgroundAccurate noise power spectra (NPS) measurement in clinical X‐ray CT exams is challenging due to the need for repeated scans, which expose patients to high radiation risks. A reliable method for single CT acquisition NPS estimation is thus highly desirable.PurposeTo develop a method for estimating local NPS from a single photon counting detector‐CT (PCD‐CT) acquisition.MethodsA novel nearly statistical bias‐free estimator was constructed from the raw counts data of PCD‐CT scan to estimate the variance of sinogram projection data. An analytical algorithm is employed to reconstruct point‐wise covariance between any two image pixel/voxel locations and . A Fourier transform is applied to obtain the desired point‐wise NPS for any chosen location . The method was validated using experimental data acquired from a benchtop PCD‐CT system with various physical phantoms, and the results were compared with the conventional local NPS measurement method using repeated scans and statistical ensemble averaging.ResultsThe experimental results demonstrate that (1) the proposed method can achieve pointwise/local NPS measurement for a region of interest (ROI) located at any chosen position, accurately characterizing the NPS with spatial structures resulting from image content heterogeneity; (2) the local NPS measured using the proposed method show a higher precision in the measured NPS compared to the conventional measurement method; (3) spatial averaging of the local NPS yields the conventional NPS for a given local ROI.ConclusionA new method was developed to enable local NPS from a single PCD‐CT acquisition.

Funder

National Institute of Biomedical Imaging and Bioengineering

National Heart, Lung, and Blood Institute

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3