Performance of the Lumipulse plasma Aβ42/40 and pTau181 immunoassays in the detection of amyloid pathology

Author:

Figdore Daniel J.1,Wiste Heather J.2,Bornhorst Joshua A.1,Bateman Randall J.3,Li Yan3,Graff‐Radford Jonathan4,Knopman David S.4,Vemuri Prashanthi5,Lowe Val J.5,Jr Clifford R. Jack5,Petersen Ronald C.4,Algeciras‐Schimnich Alicia1

Affiliation:

1. Department of Laboratory Medicine and Pathology Mayo Clinic Rochester Minnesota USA

2. Department of Quantitative Health Sciences Mayo Clinic Rochester Minnesota USA

3. Department of Neurology Washington University School of Medicine St. Louis Missouri USA

4. Department of Neurology Mayo Clinic Rochester Minnesota USA

5. Department of Radiology Mayo Clinic Rochester Minnesota USA

Abstract

AbstractINTRODUCTIONThis study evaluated the performance of the Lumipulse plasma beta‐amyloid (Aβ) 42/40 and pTau181 compared to other assays to detect an abnormal amyloid‐positron emission tomography (PET).METHODSPlasma samples from cognitively unimpaired (N = 179) and MCI/AD dementia (N = 36) individuals were retrospectively evaluated. Plasma Aβ42/40 and pTau181 were measured using the Lumipulse and Simoa immunoassays. An immunoprecipitation mass spectrometry (IP‐MS) assay for plasma Aβ42/40 was also evaluated. Amyloid‐PET status was the outcome measure.RESULTSLumipulse and IP‐MS Aβ42/40 exhibited the highest diagnostic accuracy for detecting an abnormal amyloid‐PET (areas under the curve [AUCs] of 0.81 and 0.84, respectively). The Lumipulse and Simoa pTau181 assays exhibited lower performance (AUCs of 0.74 and 0.72, respectively). The Simoa Aβ42/40 assay demonstrated the lowest diagnostic accuracy (AUC 0.57). Combining Aβ42/40 and pTau181 did not significantly improve performance over Aβ42/40 alone for Lumipulse (AUC 0.83) or over pTau181 alone for Simoa (AUC 0.71)DISCUSSIONThe Lumipulse Aβ42/40 assay showed similar performance to the IP‐MS Aβ42/40 assay for detection of an abnormal amyloid‐PET; and both assays performed better than the two p‐tau181 immunoassays. The Simoa Aβ42/Aβ40 assay was the least accurate at predicting an abnormal amyloid‐PET status.Highlights Lumipulse plasma Aβ42/Aβ40 AUC for abnormal amyloid‐PET detection was 0.81. This performance was comparable to previously reported IP‐MS and higher than Simoa. Performance of Alzheimer's disease blood biomarkers varies between assays.

Publisher

Wiley

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3