Monte Carlo based continuous aperture optimization for VMAT on conventional and MR‐linacs: A proof of concept

Author:

Su Shiqin1,Atwal Parmveer2,Popescu I Antoniu34

Affiliation:

1. Department of Radiation Oncology University of Michigan Ann Arbor Michigan USA

2. Department of Radiation Therapy BC Cancer Abbotsford British Columbia Canada

3. Department of Radiation Therapy BC Cancer Vancouver British Columbia Canada

4. Department of Physics and Astronomy University of British Columbia Vancouver British Columbia Canada

Abstract

AbstractBackgroundCurrently, the commercial treatment planning systems for magnetic‐resonance guided linear accelerators (MR‐linacs) only support step‐and‐shoot intensity‐modulated radiation therapy (IMRT). However, recent studies have shown the feasibility of delivering arc therapy on MR‐linacs, which is expected to improve dose distributions and delivery speed. By accurately accounting for the electron return effect in the presence of a magnetic field, a Monte Carlo (MC) algorithm is ideally suited for the inverse treatment planning of this technique.PurposeWe propose a novel MC‐based continuous aperture optimization (MCCAO) algorithm for volumetric modulated arc therapy (VMAT), including applications to VMAT on MR‐linacs and trajectory‐based VMAT. A unique feature of MCCAO is that the continuous character of gantry rotation and multileaf collimator (MLC) motion is accounted for at every stage of the optimization.MethodsThe optimization process uses a multistage simulation of 4D dose distribution. A phase space is scored at the top surface of the MLC and the energy deposition of each particle history is mapped to its position in this phase space. A progressive sampling method is used, where both MLC leaf positions and monitor unit (MU) weights are randomly changed, while respecting the linac mechanical limits. Due to the continuous nature of the leaf motion, such changes affect not only a single control point, but propagate to the adjacent ones as well, and the corresponding dose distribution changes are accounted for. A dose–volume cost function is used, which includes the MC statistical uncertainty.ResultsWe applied our optimization technique to various treatment sites, using standard and flattening‐filter‐free (FFF) 6 MV beam models, with and without a 1.5 T magnetic field. MCCAO generates deliverable plans, whose dose distributions are in good agreement with measurements on ArcCHECK and stereotactic radiosurgery End‐To‐End Phantom.ConclusionsWe show that the novel MCCAO method generates VMAT plans that meet clinical objectives for both conventional and MR‐linacs.

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3