Influence of the storage procedure on the trace element content measured in the aquatic moss Fontinalis antipyretica Hedw

Author:

Villares Rubén1ORCID,Vázquez María Dolores1,Real Carlos1

Affiliation:

1. Departamento de Bioloxía Funcional, Escola Politécnica Superior de Enxeñaría Universidade de Santiago de Compostela Lugo Spain

Abstract

AbstractAquatic bryophytes have been used as pollution biomonitors for decades. Despite this, sample collection and preparation methods have not been standardized, which makes it difficult to compare the results of different studies. Most times, the samples have to be stored before processing, for example, when many of them are collected in a short time, as occurs in extensive pollution studies. Storage must be done in a way that does not change the pollutant concentrations in the samples. We studied whether the concentrations of Al, As, Ba, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, and Zn in the aquatic moss Fontinalis antipyretica were affected by three storage procedures: dry at room temperature, fresh (in refrigerator at 6°C), and frozen at −20°C. In addition, we evaluated whether the subsequent washing of the samples affected the concentrations of these elements differently depending on the storage method. Our results showed that the three methods were, in general, adequate since the concentrations did not change, and we did not observe differences between washed and unwashed samples either. Since the simplest method is refrigeration, we concluded that this is the best of them. However, the concentrations of Hg increased steadily over time in the fresh material, probably because of redistribution after volatilization from the basal parts of the mosses. We believe that the respiration of the plants lowered the concentrations of oxygen inside the hermetically sealed bags containing the samples, thus promoting the reduction of the Hg and its posterior volatilization and redistribution. We did not observe interactions between the storage method and the posterior washing of the samples.Practitioner Points We studied the influence of storage procedure on element content in aquatic mosses. The procedures were as follows: dried at room temperature, stored in refrigerator, and frozen. The procedures did not change the element contents, except for Hg in refrigerator. All the procedures seemed suitable, but refrigeration was the simplest one.

Funder

Ministerio de Economía y Competitividad

Federation of European Biochemical Societies

Publisher

Wiley

Subject

Water Science and Technology,Ecological Modeling,Waste Management and Disposal,Pollution,Environmental Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3