Diagnostic performance of contrast‐enhanced mammography for suspicious findings in dense breasts: A systematic review and meta‐analysis

Author:

Lin Shu‐ting1,Li Hong‐jiang1,Li Yi‐zhong2,Chen Qian‐qian1,Ye Jia‐yi1,Lin Shu34,Cai Si‐qing1ORCID,Sun Jian‐guo5

Affiliation:

1. Department of Radiology The Second Affiliated Hospital of Fujian Medical University Quanzhou Fujian China

2. Department of Bone The Second Affiliated Hospital of Fujian Medical University Quanzhou Fujian China

3. Center of Neurological and Metabolic Research The Second Affiliated Hospital of Fujian Medical University Quanzhou Fujian China

4. Department of Neuroendocrinology, Group of Neuroendocrinology Garvan Institute of Medical Research Sydney New South Wales Australia

5. Department of Urinary Surgery The Second Affiliated Hospital of Fujian Medical University Quanzhou Fujian China

Abstract

AbstractPurposeContrast‐enhanced spectral imaging (CEM) is a new mammography technique, but its diagnostic value in dense breasts is still inconclusive. We did a systematic review and meta‐analysis of studies evaluating the diagnostic performance of CEM for suspicious findings in dense breasts.Materials and MethodsThe PubMed, Embase, and Cochrane Library databases were searched systematically until August 6, 2023. Prospective and retrospective studies were included to evaluate the diagnostic performance of CEM for suspicious findings in dense breasts. The QUADAS‐2 tool was used to evaluate the quality and risk of bias of the included studies. STATA V.16.0 and Review Manager V.5.3 were used to meta‐analyze the included studies.ResultsA total of 10 studies (827 patients, 958 lesions) were included. These 10 studies reported the diagnostic performance of CEM for the workup of suspicious lesions in patients with dense breasts. The summary sensitivity and summary specificity were 0.95 (95% CI, 0.92–0.97) and 0.81 (95% CI, 0.70–0.89), respectively. Enhanced lesions, circumscribed margins, and malignancy were statistically correlated. The relative malignancy OR value of the enhanced lesions was 28.11 (95% CI, 6.84–115.48). The relative malignancy OR value of circumscribed margins was 0.17 (95% CI, 0.07–0.45).ConclusionCEM has high diagnostic performance in the workup of suspicious findings in dense breasts, and when lesions are enhanced and have irregular margins, they are often malignant.

Funder

Natural Science Foundation of Fujian Province

Wu Jieping Medical Foundation

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3