Safety and efficacy of adaptive atrial pacing regulated by blood pressure during low‐level exercise: a proof‐of‐concept study

Author:

Burnam Michael1,Develle Robert1,Polosajian Leo2,Nalbandian Shakeh2,Ellenbogen Kenneth3,Gang Eli4

Affiliation:

1. BaroPace, Inc Issaquah WA USA

2. Cardiac Rhythm Specialists, Inc Los Angeles CA USA

3. Virginia Commonwealth University School of Medicine Richmond VA USA

4. Cardiovascular Research Foundation Beverly Hills & Cedars‐Sinai Smidt Heart Institute Los Angeles CA USA

Abstract

AbstractAimsDespite half of all heart failure patients suffering from heart failure with preserved ejection fraction (HFpEF), treatment options are limited. This study aims to compare safety and efficacy of standard pacemaker programming (DDD or DDDR) and a novel pacing algorithm PressurePace™ (BaroPace Inc, Issaquah, WA, USA) which modulates atrial pacing rate based on blood pressure (BPAP).MethodsThis prospective, randomized, double‐blind, non‐significant risk proof of concept study was conducted at two large cardiology clinics in Los Angeles, California, USA. Subjects underwent two modified Bruce protocol graded treadmill exercise tests in which pacemaker programming was randomized to either standard programming (DDD or DDDR), or BPAP at least 1 week apart. Physiological measurements of heart rate (HR), and systolic and diastolic blood pressure (BP) were collected at 2 min intervals. During the BPAP treadmill test, the pacemaker activity sensor was disabled. The PressurePace algorithm instructed the pacemaker technician to modify or leave unchanged the atrial pacing rate based on these BP measurements. Subjects and clinical staff were blinded to pacemaker programming, only the pacemaker technician was unblinded.ResultsTen subjects with HFpEF associated with hypertension who also had permanent dual‐chamber pacemakers, previously implanted for standard clinical indications, participated in the study. Mean age was 70.1 ± 6.8 years, left ventricular ejection fraction of 54.8 ± 1.9%. Exercise duration increased in all 10 subjects, when paced in the BPAP mode compared with standard pacemaker programming, showing a mean increase of 117 s (26%, P = 0.0016). The algorithm could adjust HR at each 2 min interval. The majority of subjects (60%) had their atrial pacing rate increased an average of 20% at t = 2 min. In the remaining 40% of subjects, the algorithm instructed HR to be unchanged. In two subjects, the pacing rate was not increased until t = 6 min. In contrast, subjects programmed to DDDR experienced an average of 45% increase in atrial pacing rate at t = 2 min. In the post‐treadmill recovery period, SBP was higher for subjects who underwent BPAP. This difference in SBP was most pronounced immediately post‐treadmill and diminished as subjects progressed through the 30 min recovery period. Statistical significance was achieved at t = 0, 20, and 30 min post‐treadmill.ConclusionsAn increase in exercise duration was reported in HFpEF subjects using a pacing algorithm that modulated HR based on BP compared with standard programming. These encouraging results form the basis for a larger, randomized cross‐over trial to confirm these initial observations, further characterize the safety, efficacy, and possible mechanisms of action in both acute and longer‐term treatment.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3