AbstractBackgroundOwing to its portability, affordability, and energy‐efficiency, LED‐based photoacoustic (PA) imaging is increasingly becoming popular when compared to its laser‐based alternative, mainly for superficial vascular imaging applications. However, this technique suffers from low SNR and thereby limited imaging depth. As a result, visual image quality of LED‐based PA imaging is not optimal, especially in sub‐surface vascular imaging applications.PurposeCombination of linear ultrasound (US) probes and LED arrays are the most common implementation in LED‐based PA imaging, which is currently being explored for different clinical imaging applications. Traditional delay‐and‐sum (DAS) is the most common beamforming algorithm in linear array‐based PA detection. Side‐lobes and reconstruction‐related artifacts make the DAS performance unsatisfactory and poor for a clinical‐implementation. In this work, we explored a new weighting‐based image processing technique for LED‐based PAs to yield improved image quality when compared to the traditional methods.MethodsWe are proposing a lag‐coherence factor (LCF), which is fundamentally based on the combination of the spatial auto‐correlation of the detected PA signals. In LCF, the numerator contains lag‐delay‐multiply‐and‐sum (DMAS) beamformer instead of a conventional DAS beamformer. A spatial auto‐correlation operation is performed between the detected US array signals before using DMAS beamformer. We evaluated the new method on both tissue‐mimicking phantom (2D) and human volunteer imaging (3D) data acquired using a commercial LED‐based PA imaging system.ResultsOur novel correlation‐based weighting technique showed LED‐based PA image quality improvement when it is combined with conventional DAS beamformer. Both phantom and human volunteer imaging results gave a direct confirmation that by introducing LCF, image quality was improved and this method could reduce side‐lobes and artifacts when compared to the DAS and coherence‐factor (CF) approaches. Signal‐to‐noise ratio, generalized contrast‐to‐noise ratio, contrast ratio and spatial resolution were evaluated and compared with conventional beamformers to assess the reconstruction performance in a quantitative way. Results show that our approach offered image quality enhancement with an average signal‐to‐noise ratio and spatial resolution improvement of around 20% and 25% respectively, when compared with conventional CF based DAS algorithm.ConclusionsOur results demonstrate that the proposed LCF based algorithm performs better than the conventional DAS and CF algorithms by improving signal‐to‐noise ratio and spatial resolution. Therefore, our new weighting technique could be a promising tool to improve the performance of LED‐based PA imaging and thus accelerate its clinical translation.

Publisher

Wiley

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3