Affiliation:
1. Anhui Provincial Center of Drug Clinical Evaluation Yijishan Hospital of Wannan Medical College Wuhu Anhui People's Republic of China
2. School of pharmacy Wannan Medical College Wuhu Anhui People's Republic of China
3. Jiangsu Wangao Pharmaceutical Co., Ltd. Nantong Jiangsu People's Republic of China
Abstract
AbstractA liquid chromatography–tandem mass spectrometry method with vonoprazan fumarate‐d4 as a stable isotope‐labeled internal standard was developed and validated aiming at quantification of vonoprazan fumarate in human plasma for a bioequivalence study. Chromatographic separation was achieved by acetonitrile one‐step protein precipitation using a gradient elution of 0.1% formic acid aqueous solution and acetonitrile with a run time of 3.65 min. Detection was carried out on a tandem mass spectrometer in multiple reaction monitoring mode via a positive electrospray ionization interface. The multiple reaction monitoring mode of precursor–product ion transitions for vonoprazan fumarate and vonoprazan fumarate‐d4 were m/z 346.0 → 315.1 and 350.0 → 316.0, respectively. The linear range was 0.150–60.000 ng/ml. This method was fully validated with acceptable results in terms of selectivity, carryover, lower limit of quantification, calibration curve, accuracy, precision, dilution effect, matrix effect, stability, recovery and incurred sample reanalysis. A successful application of this method was realized in the bioequivalence study of vonoprazan fumarate tablet (20 mg) among healthy Chinese volunteers.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献