Detection of acetone in the human breath as diabetes biomarker based on PPy/WO3 nanocomposite sensor by FFT continuous cyclic voltammetry method

Author:

Alizadeh Naader1ORCID,Amiri Mahsa1,Mohammadpour Fariba1,Norouzi Parviz2

Affiliation:

1. Department of Chemistry Faculty of Basic Sciences Tarbiat Modares University P.O. Box 14115–175 Tehran Iran

2. Center of Excellence in Electrochemistry School of Chemistry College of Science University of Tehran postcode is missing Tehran Iran

Abstract

AbstractThis research represents a novel detection method of acetone level in the exhaled breath samples (RH=88 %) based on polypyrrole/tungsten oxide (PPy/WO3) nanocomposite sensor. The PPy/WO3 sensor was fabricated by the deposition of nanocomposite on/between interdigitated electrodes (IDEs) through electrospray coating and was then characterized by FE‐SEM imaging. In this detection method, the coulometric signal of the sensor was calculated using Fast Fourier Continuous Cyclic Voltammetry (FFTCCV), where cyclic voltammetry (CV) was applied to the sensor in the defined potential rang and then charge changes of the sensor was obtained by integration of the current in all scanned potential ranges. FFTCCV method enhances the sensitivity of the sensor when exposed to the gas mixtures containing acetone. In addition to its fast coulometric response time (≤5 s) in the two linear ranges of 0.7–2.8 ppm and 2.8–28.2 ppm (R2=0.99), FFTCCV method provides the low detection limit of 70 ppb, and high sensitivity toward acetone at the optimum values of the parameters. The fabricated sensor showed great selectivity toward acetone when exposed to humid air and some exhaled gas like carbon dioxide, ammonia, methanol, ethanol and alkyl amines. The results were very satisfying as the sensor was capable to detect different acetone levels in human exhaled breath as non‐invasive diagnosis of diabetes with a good correlation (R2≃0.9) to the routine blood sugar test taken by different commercial glucometers results.

Publisher

Wiley

Subject

Electrochemistry,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3