Wideband receive‐coil array design using high‐impedance amplifiers for broadband decoupling

Author:

Sun Chenhao12ORCID,Bauer Courtney C.1ORCID,Hou Jue1ORCID,Wright Steven M.13ORCID

Affiliation:

1. Department of Electrical and Computer Engineering Texas A&M University College Station Texas USA

2. Department of Radiology and Biomedical Imaging Yale University New Haven Connecticut USA

3. Department of Biomedical Engineering Texas A&M University College Station Texas USA

Abstract

AbstractPurposeMultinuclear MRI/S is of increasing interest. Currently, most multinuclear receive array coils are constructed by nesting multiple single‐tuned array coils or using switching elements to control the operating frequency, in which case more than one set of conventional isolation preamplifiers and associated decoupling circuits is required. These conventional configurations rapidly become complicated when greater numbers of channels or nuclei are needed. In this work, a novel coil decoupling mechanism is proposed to enable broadband decoupling for array coils with one set of preamplifiers.MethodsInstead of using conventional isolation preamplifiers, a high‐input impedance preamplifier is proposed to create broadband decoupling of the array elements. A matching network consisting of a single inductor‐capacitor‐capacitor multi‐tuned network and a wire‐wound transformer was used to interface the surface coil to the high‐impedance preamplifier. To validate the concept, the proposed configuration was compared to the conventional preamplifier decoupling configuration on both bench and scanner.Results2 The approach can provide more than 15dB decoupling over a range of 25MHz, covering the Larmor frequencies of 23Na and 2H at 4.7T. This multi–tuned prototype obtained 61% and 76% of the imaging SNR at 2H and 23Na respectively, 76 and 89% in a higher loading test phantom, when compared to the conventional single–tuned preamplifier decoupling configuration.ConclusionWith the multinuclear array operation and decoupling achieved using only one layer of array coil and preamplifiers, this work provides a simple approach of building high element‐count arrays to enable accelerated imaging or SNR improvement from multiple nuclei.

Funder

National Institutes of Health

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

Reference57 articles.

1. BoskampE.A new revolution in surface coil technology: the array surface coil. In Proceedings of the 6th Annual Meeting of the SMRM New York NY 1987. p. 405.

2. Switched array coils

3. RequardtH TyrellR.Switched array coils: a new multipurpose tool in MRI. In Proceedings of the 6th Annual Meeting of the SMRM New York NY 1987. p. 408.

4. WrightS MaginR KeltonJ.Arrays of mutually coupled local coils for high resolution MR imaging. In Proceedings of the 6th Annual Meeting of the SMRM New York NY 1987.

5. Arrays of mutually coupled receiver coils: Theory and application

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Any‐nucleus distributed active programmable transmit coil;Magnetic Resonance in Medicine;2024-02-11

2. An Exploration of a Phased-Array RF Coil for Very Low-Field Brain MRI;IEEE Sensors Journal;2024-02-01

3. A Four-Channel Broadband MRI Receive Array Coil;2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC);2023-07-24