Optimization of acquisition parameters for cortical inhomogeneous magnetization transfer (ihMT) imaging using a rapid gradient echo readout

Author:

Rowley Christopher D.12ORCID,Campbell Jennifer S. W.1,Leppert Ilana R.1,Nelson Mark C.12ORCID,Pike G. Bruce3,Tardif Christine L.124ORCID

Affiliation:

1. McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital McGill University Montreal Québec Canada

2. Department of Neurology and Neurosurgery McGill University Montreal Québec Canada

3. Hotchkiss Brain Institute and Departments of Radiology and Clinical Neuroscience, Cumming School of Medicine University of Calgary Calgary Alberta Canada

4. Department of Biomedical Engineering McGill University Montreal Québec Canada

Abstract

PurposeImaging biomarkers with increased myelin specificity are needed to better understand the complex progression of neurological disorders. Inhomogeneous magnetization transfer (ihMT) imaging is an emergent technique that has a high degree of specificity for myelin content but suffers from low signal to‐noise ratio (SNR). This study used simulations to determine optimal sequence parameters for ihMT imaging for use in high‐resolution cortical mapping.MethodsMT‐weighted cortical image intensity and ihMT SNR were simulated using modified Bloch equations for a range of sequence parameters. The acquisition time was limited to 4.5 min/volume. A custom MT‐weighted RAGE sequence with center‐out k‐space encoding was used to enhance SNR at 3 T. Pulsed MT imaging was studied over a range of saturation parameters, and the impact of the turbo factor on the effective ihMT resolution was investigated. 1 mm isotropic ihMTsat maps were generated in 25 healthy adults.ResultsGreater SNR was observed for larger number of bursts consisting of 6–8 saturation pulses each, combined with a high readout turbo factor. However, that protocol suffered from a point spread function that was more than twice the nominal resolution. For high‐resolution cortical imaging, we selected a protocol with a higher effective resolution at the cost of a lower SNR. We present the first group‐average ihMTsat whole‐brain map at 1 mm isotropic resolution.ConclusionThis study presents the impact of saturation and excitation parameters on ihMTsat SNR and resolution. We demonstrate the feasibility of high‐resolution cortical myelin imaging using ihMTsat in less than 20 min.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3