Structured low‐rank reconstruction for navigator‐free water/fat separated multi‐shot diffusion‐weighted EPI

Author:

Dong Yiming1ORCID,Koolstra Kirsten2ORCID,Li Ziyu3ORCID,Riedel Malte4ORCID,van Osch Matthias J. P.1ORCID,Börnert Peter15

Affiliation:

1. C.J. Gorter MRI Center, Department of Radiology LUMC Leiden The Netherlands

2. Philips Best The Netherlands

3. Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences University of Oxford Oxford UK

4. University and ETH Zurich Zurich Switzerland

5. Philips Research Hamburg Hamburg Germany

Abstract

AbstractPurposeMulti‐shot diffusion‐weighted EPI allows an increase in image resolution and reduced geometric distortions and can be combined with chemical‐shift encoding (Dixon) to separate water/fat signals. However, such approaches suffer from physiological motion‐induced shot‐to‐shot phase variations. In this work, a structured low‐rank‐based navigator‐free algorithm is proposed to address the challenge of simultaneously separating water/fat signals and correcting for physiological motion‐induced shot‐to‐shot phase variations in multi‐shot EPI‐based diffusion‐weighted MRI.Theory and MethodsWe propose an iterative, model‐based reconstruction pipeline that applies structured low‐rank regularization to estimate and eliminate the shot‐to‐shot phase variations in a data‐driven way, while separating water/fat images. The algorithm is tested in different anatomies, including head–neck, knee, brain, and prostate. The performance is validated in simulations and in‐vivo experiments in comparison to existing approaches.ResultsIn‐vivo experiments and simulations demonstrated the effectiveness of the proposed algorithm compared to extra‐navigated and an alternative self‐navigation approach. The proposed algorithm demonstrates the capability to reconstruct in the multi‐shot/Dixon hybrid space domain under‐sampled datasets, using the same number of acquired EPI shots compared to conventional fat‐suppression techniques but eliminating fat signals through chemical‐shift encoding. In addition, partial Fourier reconstruction can also be achieved by using the concept of virtual conjugate coils in conjunction with the proposed algorithm.ConclusionThe proposed algorithm effectively eliminates the shot‐to‐shot phase variations and separates water/fat images, making it a promising solution for future DWI on different anatomies.

Funder

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3