A Solution‐Processable Porphyrin‐Based Hydrogen‐Bonded Organic Framework for Photoelectrochemical Sensing of Carbon Dioxide

Author:

Wang Chen1ORCID,Song Xiyu1ORCID,Wang Yao1ORCID,Xu Rui1,Gao Xiangyu1,Shang Cheng1,Lei Peng2,Zeng Qingdao2,Zhou Yaming1,Chen Banglin3ORCID,Li Peng1ORCID

Affiliation:

1. Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials Department of Chemistry Fudan University 2005 Songhu Road Shanghai 200438 China

2. CAS Key Laboratory of Standardization and Measurement for Nanotechnology CAS Center for Excellence in Nanoscience Department of Chemistry and International Institute of Nanotechnology National Center for Nanoscience and Technology (NCNST) No. 11 Beiyitiao, Zhongguancun Beijing 100190 China

3. Fujian Provincial Key Laboratory of Polymer Materials College of Chemistry and Materials Science Fujian Normal University Fuzhou 350007 China

Abstract

AbstractDetecting CO2 in complex gas mixtures is challenging due to the presence of competitive gases in the ambient atmosphere. Photoelectrochemical (PEC) techniques offer a solution, but material selection and specificity remain limiting. Here, we constructed a hydrogen‐bonded organic framework material based on a porphyrin tecton decorated with diaminotriazine (DAT) moieties. The DAT moieties on the porphyrin molecules not only facilitate the formation of complementary hydrogen bonds between the tectons but also function as recognition sites in the resulting porous HOF materials for the selective adsorption of CO2. In addition, the in‐plane growth of FDU‐HOF‐2 into anisotropic molecular sheets with large areas of up to 23000 μm2 and controllable thickness between 0.298 and 2.407 μm were realized in yields of over 89 % by a simple solution‐processing method. The FDU‐HOF‐2 can be directly grown and deposited onto different substrates including silica, carbon, and metal oxides by self‐assembly in situ in formic acid. As a proof of concept, a screen‐printing electrode deposited with FDU‐HOF‐2 was fabricate as a label‐free photoelectrochemical (PEC) sensor for CO2 detection. Such a signal‐off PEC sensor exhibits low detection limit for CO2 (2.3 ppm), reusability (at least 30 cycles), and long‐term working stability (at least 30 days).

Funder

State Key Laboratory for Modification of Chemical Fibers and Polymer Materials

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3