Spatial resolution, noise properties, and detectability index of a deep learning reconstruction algorithm for dual‐energy CT of the abdomen

Author:

Thor Daniel12,Titternes Rebecca13,Poludniowski Gavin13

Affiliation:

1. Department of Medical Radiation Physics and Nuclear Medicine Karolinska University Hospital Stockholm Sweden

2. Department of Oncology‐Pathology Karolinska Institutet Stockholm Sweden

3. Department of Clinical Science Intervention and Technology Karolinska Institutet Stockholm Sweden

Abstract

AbstractBackgroundIterative reconstruction (IR) has increasingly replaced traditional reconstruction methods in computed tomography (CT). The next paradigm shift in image reconstruction is likely to come from artificial intelligence, with deep learning reconstruction (DLR) solutions already entering the clinic. An enduring disadvantage to IR has been a change in noise texture, which can affect diagnostic confidence. DLR has demonstrated the potential to overcome this issue and has recently become available for dual‐energy CT.PurposeTo evaluate the spatial resolution, noise properties, and detectability index of a commercially available DLR algorithm for dual‐energy CT of the abdomen and compare it to single‐energy (SE) CT.MethodsAn oval 25 cm x 35 cm custom‐made phantom was scanned on a GE Revolution CT scanner (GE Healthcare, Waukesha, WI) at two dose levels (13 and 5 mGy) and two iodine concentrations (8 and 2 mg/mL), using three typical abdominal scan protocols: dual‐energy (DE), SE 80 kV (SE‐80 kV) and SE 120 kV (SE‐120 kV). Reconstructions were performed with three strengths of IR (ASiR‐V: AR0%, AR50%, AR100%) and three strengths of DLR (TrueFidelity: low, medium, high). The DE acquisitions were reconstructed as mono‐energetic images between 40 and 80 keV. The noise power spectrum (NPS), task transfer function (TTF), and detectability index (d’) were determined for the reconstructions following the recommendations of AAPM Task Group 233.ResultsNoise magnitude reductions (relative to AR0%) for the SE protocols were on average (−29%, −21%) for (AR50%, TF‐M), while for DE‐70 keV were (−28%, −43%). There was less reduction in mean frequency (fav) for DLR than for IR, with similar results for SE and DE imaging. There was, however, a substantial change in the NPS shape when using DE with DLR, quantifiable by a marked reduction in the peak frequency (fpeak) that was absent in SE mode. All protocols and reconstructions (including AR0%) exhibited slight to moderate shifts towards lower spatial frequencies at the lower dose (<12% in fav). Spatial resolution was consistently superior for DLR compared to IR for SE but not for DE. All protocols and reconstructions (including AR0%) showed decreased resolution with reduced dose and iodine concentration, with less decrease for DLR compared to IR. DLR displayed a higher d’ than IR. The effect of energy was large: d’ increased with lower keV, and SE‐80 kV had higher d’ than SE‐120 kV. Using DE with DLR could provide higher d’ than SE‐80 kV at the higher dose but not at lower dose.ConclusionsDE imaging with DLR maintained spatial resolution and reduced noise magnitude while displaying less change in noise texture than IR. The d’ was also higher with DLR than IR, suggesting superiority in detectability of iodinated contrast. Despite these trends being consistent with those previously established for SE imaging, there were some noteworthy differences. For DE imaging there was no improvement in resolution compared to IR and a change in noise texture. DE imaging with low keV and DLR had superior detectability to SE DLR at the high dose but was not better than SE‐80 kV at low dose.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3