Automatic dose prediction using deep learning and plan optimization with finite‐element control for intensity modulated radiation therapy

Author:

Shen Yichao1,Tang Xingni1,Lin Sara2,Jin Xiance3,Ding Jiapei1,Shao Minghai1

Affiliation:

1. Department of Radiation Oncology Taizhou Hospital Taizhou Zhejiang People's Republic of China

2. Petrone associates Staten Island New York USA

3. Radiotherapy Center Department The First Affiliated Hospital of Wenzhou Medical University Wenzhou Zhejiang People's Republic of China

Abstract

AbstractBackgroundAutomatic solutions for generating radiotherapy treatment plans using deep learning (DL) have been investigated by mimicking the voxel's dose. However, plan optimization using voxel‐dose features has not been extensively studied.PurposeThis study aims to investigate the efficiency of a direct optimization strategy with finite elements (FEs) after DL dose prediction for automatic intensity‐modulated radiation therapy (IMRT) treatment planning.MethodsA double‐UNet DL model was adapted for 220 cervical cancer patients (200 for training and 20 for testing), who underwent IMRT between 2016 and 2020 at our clinic. The model inputs were computed tomography (CT) slices, organs at risk (OARs), and planning target volumes (PTVs), and the outputs were dose distributions of uniformly generated high‐dose region‐controlled plans. The FEs were discretized into equal intervals of the dose prediction value within the [OARs avoid PTV(O‐P)] and [body avoids OARs & PTV(B‐OP)] regions in the test cohort and used to define the objectives for IMRT plan optimization. The plans were optimized using a two‐step process. In the beginning, the plans of two extra cases with and without low‐dose region control were compared to pursue robust and optimal dose adjustment degree pattern of FEs. In the first step, the mean dose of O‐P FEs were constrained to differing degrees according to the pattern. The further the FEs from the PTV, the tighter the constraints. In the second step, the mean dose of O‐P FEs from first step were constrained again but weakly and the dose of the B‐OP FEs from dose prediction and PTV were tightly regulated. The dosimetric parameters of the OARs and PTV were evaluated and compared using an interstep approach. In another 10 cases, the plans optimized via the aforementioned steps (method 1) were compared with those directly generated by the double‐UNet dose prediction model trained by low and high region‐controlled plans (method 2).ResultsThe mean differences in dose metrics between the UNet‐predicted dose and the clinical plans were: 0.47 Gy for bladder D50%; 0.62 Gy for rectum D50%; 0% for small intestine V30Gy; 1% for small intestine V40Gy; 4% for left femoral head V30Gy; and 6% for right femoral head V30Gy. The reductions in mean dose (p < 0.001) after FE‐based optimization were: 4.0, 1.9, 2.8, 5.9, and 5.7 Gy for the bladder, rectum, small intestine, left femoral head, and right femoral head, respectively, with flat PTV homogeneity and conformity. Method 1 plans produced lower mean doses than those of method 2 for the bladder (0.7 Gy), rectum (1.0 Gy), and small intestine (0.6 Gy), while maintaining  PTV homogeneity and conformity.ConclusionFE‐based direct optimization produced lower OAR doses and adequate PTV doses after DL prediction. This solution offers rapid and automatic plan optimization without manual adjustment, particularly in low‐dose regions.

Funder

Science and Technology Plan Project of Taizhou

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3