Time–frequency signal analysis of flow pulsation in siphon outlet conduit based on HHT considering the pump‐conduit interaction

Author:

Yang Fan12ORCID,Lin Zhikang1,Ding Ping13,Jin Xiaoyu1,Tang Fangping1,Yuan Yao4

Affiliation:

1. College of Hydraulic Science and Engineering Yangzhou University Yangzhou China

2. Hydrodynamic Engineering Laboratory of Jiangsu Province Yangzhou China

3. Water Conservancy Project Construction Center of Yangzhou City Yangzhou China

4. Water Resources Research Institute of Jiangsu Province Nanjing China

Abstract

AbstractThe unsteady three‐dimensional numerical simulation calculation of the vertical axial flow pump device is performed based on CFD to examine the pressure pulsation and energy distribution features of the water flow within the siphon outlet conduit (SOC) under the hydraulic coupling of the pump and the flow conduit. The pressure pulsation signals (PPS) of monitoring points are decomposed using the Hilbert–Huang approach via empirical mode decomposition (EMD) and Hilbert spectrum analysis. The results show that the PPS of monitoring points of the SOC has no obvious periodicity. The low‐frequency range below 20 Hz serves as the primary frequency, and the energy ratio of the high‐frequency signal above 700 Hz is less than 1%. Under the condition of a small flow rate 0.3Qbep, there is obvious high‐frequency pulsation above 500 Hz at the inlet of the upstream section of the SOC, and there are periodic components distributed around 200 Hz. The energy of the pressure pulsation is primarily focused in the low‐frequency range below 40 Hz at the SOC outlet section. The PPS at the top and bottom monitoring points of the hump section are consistent, and the pressure pulsation energy (PPE) is mainly concentrated in the low frequency below 40 Hz. In both the big flow condition (1.2Qbep) and the optimal flow condition (1.0Qbep), the PPE of the monitoring points at the top of the hump section is distributed in the middle and low‐frequency band below 40 Hz, and the energy of monitoring points at the bottom of the hump section is concentrated in the low‐frequency band below 20 Hz, accounting for more than 70%. When the flow rate increases from 0.3Qbep to 1.2Qbep, the peak value of the pressure pulsation coefficient at the main frequency of each monitoring point at the top of the hump section changes little, and the peak value of the pressure pulsation coefficient at the main frequency of each monitoring point at the bottom increases first and then decreases. From the upstream section to the hump section of the SOC, the average frequency of each intrinsic mode function (IMF) of the PPS under different flow conditions shows an overall increasing trend. From the hump section of the SOC to its outlet, the average frequency of each IMF of the PPS decreases under the conditions of 1.0Qbep and 1.2Qbep, and there is no obvious change under the condition of 0.3Qbep.

Funder

National Natural Science Foundation of China

Publisher

Wiley

Subject

General Energy,Safety, Risk, Reliability and Quality

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3