High‐dimensional automated radiation therapy treatment planning via Bayesian optimization

Author:

Wang Qingying12,Wang Ruoxi1,Liu Jiacheng12,Jiang Fan1,Yue Haizhen1,Du Yi12,Wu Hao12

Affiliation:

1. Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing) Department of Radiation Oncology, Beijing Cancer Hospital & Institute Beijing China

2. Institute of Medical Technology Peking University Health Science Center Beijing China

Abstract

AbstractPurposeRadiation therapy treatment planning can be viewed as an iterative hyperparameter tuning process to balance conflicting clinical goals. In this work, we investigated the performance of modern Bayesian optimization (BO) methods on automated treatment planning problems in high‐dimensional settings.MethodsTwenty locally advanced rectal cancer patients treated with intensity‐modulated radiation therapy (IMRT) were retrospectively selected as test cases. The adjustable planning parameters included both dose objectives and their corresponding weights. We implemented an automated treatment planning framework and tested the performance of two BO methods on the treatment planning task: one standard BO method (Gaussian Process with Expected Improvement [GPEI]) and one BO method dedicated to high‐dimensional problems (Sparse Axis Aligned Subspace BO [SAAS‐BO]). Another derivative‐free method (Nelder–Mead simplex search) and the random tuning method were also included as baselines. The four automated methods' plan quality and planning efficiency were compared with the clinical plans regarding target coverage and organs at risk (OAR) sparing. The predictive models in both BO methods were compared to analyze the different search patterns of the two BO methods.ResultsFor the target structures, the SAAS‐BO plans achieved comparable hot spot control () and homogeneity () with the clinical plans, significantly better than the GPEI and Nelder–Mead plans (). Both SAAS‐BO and GPEI plans significantly outperformed the clinical plans in conformity and dose spillage (). Compared with the clinical plans, the treatment plans generated by the four automated methods all made reductions in evaluated dosimetric indices for the femoral head and the bladder. The Nelder–Mead plans achieved similar plan quality scores compared with the BO plans, but exhibited poorer control in the target hot spot and dose spillage. The analysis of the underlying predictive models has shown that both BO methods have identified similar sensitive planning parameters.ConclusionsThis work implemented a BO‐based hyperparameter tuning framework for automated treatment planning. Both tested BO methods were able to produce high‐quality treatment plans and reduce the workload of treatment planners. The model analysis also confirmed the intrinsic low dimensionality of the tested treatment planning problems.

Funder

Natural Science Foundation of Beijing Municipality

National Key Research and Development Program of China

National Natural Science Foundation of China

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3