A numerical investigation for the development of functionally graded Ti/HA tibial implant for total ankle replacement: Influence of material gradation law and volume fraction index

Author:

Jyoti 1ORCID,Ghosh Rajesh1ORCID

Affiliation:

1. Biomechanics Research Laboratory, School of Mechanical & Materials Engineering Indian Institute of Technology Mandi Mandi Himachal Pradesh India

Abstract

AbstractStress shielding is one of the major concerns for total ankle replacement implants nowadays, because it is responsible for implant‐induced bone resorption. The bone resorption contributes to the aseptic loosening and failure of ankle implants in later stages. To reduce the stress shielding, improvements can be made in the implant material by decreasing the elastic mismatch between the implant and the tibia bone. This study proposes a new functionally graded material (FGM) based tibial implant for minimizing the problem of stress shielding. Three‐dimensional finite element (FE) models of the intact tibia and the implanted tibiae were created to study the influence of material gradation law and volume fraction index on stress shielding and implant‐bone micromotion. Different implant materials were considered that is, cobalt–chromium, titanium (Ti), and FGM with Ti at the bottom and hydroxyapatite (HA) at the top. The FE models of FGM implants were generated by using different volume fractions and the rule of mixtures. The rule of mixtures was used to calculate the FGM properties based on the local volume fraction. The volume fraction was defined by using exponential, power, and sigmoid laws. For the power and sigmoid law varying volume fraction indices (0.1, 0.2, 0.5, 1, 2, and 5) were considered. The geometry resembling STAR® ankle system tibial implant was considered for the present study. The results indicate that FGMs lower stress shielding but also marginally increase implant‐bone micromotion; however, the values were within the acceptable limit for bone ingrowth. It is observed that the material gradation law and volume fraction index influence the performance of FGM tibial implants. The tibial implant composed of FGM using power law with a volume fraction index of 0.1 was the preferred option because it showed the least stress shielding.

Publisher

Wiley

Reference65 articles.

1. Functional gradient metallic biomaterials: techniques, current scenery, and future prospects in the biomedical field;Shi H;Front Bioeng Biotechnol,2021

2. Promises of Functionally Graded Material in Bone Regeneration: Current Trends, Properties, and Challenges

3. Total ankle replacement: why, when and how?;Bonasia DE;Iowa Orthop J,2010

4. A Review on Biomaterials for Orthopaedic Surgery and Traumatology: From Past to Present

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Design of functionally graded porous lattice structure tibial implant for TAR;International Journal of Mechanical Sciences;2024-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3