ROX (Respiratory rate–OXygenation) index to predict early response to high‐flow nasal cannula therapy in infants with viral bronchiolitis

Author:

Milesi Christophe1ORCID,Nogue Erika2,Baleine Julien1,Moulis Lionel2ORCID,Pouyau Robin3,Gavotto Arthur1ORCID,Brosssier David4ORCID,Mortamet Guillaume5ORCID,Cambonie Gilles1ORCID,

Affiliation:

1. Pediatric Intensive Care Unit Arnaud de Villeneuve University Hospital Montpellier France

2. Clinical Research and Epidemiology Unit, CHU Montpellier Univ Montpellier Montpellier France

3. Pediatric Intensive Care Unit Woman‐Mother‐Child University Hospital Lyon France

4. Pediatric Intensive Care Unit University Hospital Caen‐Normandy France

5. Pediatric Intensive Care Unit Grenoble University Hospital La Tronche France

Abstract

AbstractIntroductionHigh‐flow nasal cannula (HFNC) is commonly used as first step respiratory support in infants with moderate‐to‐severe acute viral bronchiolitis (AVB). This device, however, fails to effectively manage respiratory distress in about a third of patients, and data are limited on determinants of patient response. The respiratory rate–oxygenation (ROX) index is a relevant tool to predict the risk for HFNC failure in adult patients with lower respiratory tract infections. The primary objective of this study was to assess the relationship between ROX indexes collected before and 1 h after HFNC initiation, and HFNC failure occurring in the following 48 h in infants with AVB.MethodThis is an ancillary study to the multicenter randomized controlled trial TRAMONTANE 2, that included 286 infants of less than 6 months with moderate‐to‐severe AVB. Collection of physiological variables at baseline (H0), and 1 h after HFNC (H1), included heart rate (HR), respiratory rate (RR), fraction of inspired oxygen (FiO2), respiratory distress score (modified Wood's Clinical Asthma Score [mWCAS]), and pain and discomfort scale (EDIN). ROX and ROX‐HR were calculated as and , respectively. Predefined HFNC failure criteria included increase in respiratory distress score or RR, increase in discomfort, and severe apnea episodes. The accuracies of ROX, ROX‐HR indexes and clinical variable to predict HFNC failure were assessed using receiver operating curve analysis. We analyzed predictive factors of HFNC failure using multivariate logistic regressions.ResultHFNC failure occurred in 111 of 286 (39%) infants, and for 56 (50% of the failure) of them within the first 6 h. The area under the curve of ROX indexes at H0 and H1 were, respectively, 0.56 (95% confidence interval [CI] 0.48–0.63, p = 0.14), 0.56 (95% CI 0.49–0.64, p = 0.09). ROX‐HR performances were better but remained poorly discriminant. HFNC failure was associated with higher mWCAS score at H1 (p < 0.01) and lower decrease in EDIN scale during the first hour of HFNC delivery (p = 0.02). In the multivariate analyses, age and mWCAS score were were found to be independent factors associated with HFNC failure at H0. At H1, weight and mWCAS were associated factors.ConclusionIn this study, neither ROX index, nor physiological variables usually collected in infants with AVB had early discriminatory capacity to predict HFNC failure.

Publisher

Wiley

Subject

Pulmonary and Respiratory Medicine,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3