Assessing the performance of a targeted absolute quantification isotope dilution liquid chromatograhy tandem mass spectrometry assay versus a commercial nontargeted relative quantification assay for detection of three major perfluoroalkyls in human blood

Author:

Salihovic Samira1ORCID,Dunder Linda23,Lind Monica2,Lind Lars3

Affiliation:

1. School of Medical Sciences, Faculty of Medicine and Health Örebro University Örebro Sweden

2. Department of Medical Sciences, Occupational and Environmental Medicine Uppsala University Uppsala Sweden

3. Department of Medical Sciences, Cardiovascular Epidemiology Uppsala University Uppsala Sweden

Abstract

AbstractIsotope dilution ultrahigh‐performance liquid chromatography coupled to tandem mass spectrometry (UHPLC–MS/MS) is commonly used for trace analysis of polyfluoroalkyl and perfluoroalkyl substances (PFAS) in difficult matrices. Commercial nontargeted analysis of major PFAS where relative concentrations are obtained cost effectively is rapidly emerging and is claimed to provide comparable results to that of absolute quantification using matrix matched calibration and isotope dilution UHPLC–MS/MS. However, this remains to be demonstrated on a large scale. We aimed to assess the performance of a targeted absolute quantification isotope dilution LC–MS/MS assay versus a commercial nontargeted relative quantification assay for detection of three major PFAS in human blood. We evaluated a population‐based cohort of 503 individuals. Correlations were assessed using Spearman's rank correlation coefficients (rho). Precision and bias were assessed using Bland–Altman plots. For perfluorooctane sulfonic acid, the median concentrations were 5.10 ng/mL (interquartile range [IQR] 3.50–7.24 ng/mL), the two assays correlated with rho 0.83. For perfluorooctanoic acid, the median concentrations were 2.14 ng/mL (IQR 1.60–3.0 ng/mL), the two assays correlated with rho 0.92. For perfluorohexanesulfonate, the median concentrations were 5.5 ng/mL (IQR 2.50–11.61 ng/mL), the two assays correlated with rho 0.96. The Bland–Altman statistical test showed agreement of the mean difference for the majority of samples (97–98%) between the two assays. Absolute plasma concentrations of PFAS obtained using matrix matched calibration and isotope dilution UHPLC–MS/MS show agreement with relative plasma concentrations from a nontargeted commercial platform by Metabolon. We observed striking consistency between the two assays when examining the associations of the three PFAS with cholesterol, offering additional confidence in the validity of utilizing the nontargeted approach for correlations with various health phenotypes.

Funder

Svenska Forskningsrådet Formas

Publisher

Wiley

Subject

Spectroscopy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3